Introduction: The accurate placement of the ventricular catheter (VC) is critical in reducing the incidence of proximal failure of ventriculoperitoneal shunts (VPSs). The standard freehand technique is based on validated external anatomical landmarks but remains associated with a relatively high rate of VC malposition. Already proposed alternative methods have all their specific limitations. Herein, we evaluate the accuracy of our adapted freehand technique based on an individualized radio-anatomical approach. Reproducing the preoperative imaging on the patient's head using common anatomical landmarks allows to define stereotactic VC coordinates to be followed at surgery.
Material And Methods: Fifty-five consecutive patients treated with 56 VPS between 11/2005 and 02/2020 fulfilled the inclusion criteria of this retrospective study. Burr hole coordinates, VC trajectory, and length were determined in all cases on preoperative computed tomography (CT) scan and were accurately reported on patients' head. The primary endpoint was to evaluate VC placement accuracy. The secondary endpoint was to evaluate the rate and nature of postoperative VC-related complications.
Results: Our new technique was applicable in all patients and no VC-related complications were observed. Postoperative imaging showed VC optimally placed in 85.7% and sub-optimally placed in 14.3% of cases. In all procedures, all the holes on the VC tip were found in the ventricular system.
Conclusions: This simple individualized technique improves the freehand VC placement in VPS surgery, making its accuracy comparable to that of more sophisticated and expensive techniques. Further randomized controlled studies are required to compare our results with those of the other available techniques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00701-020-04702-1 | DOI Listing |
Pathogens
December 2024
Intensive Care Unit, Department of Anesthesiology and Critical Care, AHEPA University Hospital, Aristotle University of Thessaloniki, 54636 Thessaloniki, Greece.
Ventriculo-meningitis or nosocomial meningitis/ventriculitis is a severe nosocomial infection that is associated with devastating neurological sequelae. The cerebrospinal fluid isolates associated with the infection can be Gram-positive or -negative, while the spp. is rarely identified.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.
Background: Pulsed-field ablation (PFA) is an innovative non-thermal method for arrhythmia treatment. The efficacy of various PFA configurations in relation to contact force (CF) has not been well-studied in vivo.
Objectives: This study evaluated the effect of CF on acute bipolar PFA lesions in both a vegetal and an in vivo porcine heart model.
J Cardiovasc Dev Dis
December 2024
Department of Cardiology, Rush University Medical Center, Chicago, IL 60612, USA.
Pulsed field ablation (PFA) is a catheter-based procedure that utilizes short high voltage and short-duration electrical field pulses to induce tissue injury. The last decade has yielded significant scientific progress and quickened interest in PFA as an energy modality leading to the emergence of the clinical use of PFA technologies for the treatment of atrial fibrillation. It is generally agreed that more research is needed to improve our biophysical understanding of PFA for clinical cardiac applications as well as its potential as a potential alternative energy source to thermal ablation modalities for the treatment of other arrhythmias.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).
Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Biosense Webster, Inc, Irvine, CA (J.M., T.S., S.F.-H.).
Background: Sequential application of radiofrequency with pulsed field (PF) ablation may increase lesion depth while preserving the advantages of PF. The study's aim was to determine lesion dimensions of sequential, colocalized radiofrequency and PF ablation.
Methods: A preclinical study using swine (n=4) performed lesions in the right/left ventricles.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!