Predictive value of 4-Hydroxyglutamate and miR-149-5p on eclampsia.

Exp Mol Pathol

Department of Obstetrics and Gynecology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu 610072, P.R. China. Electronic address:

Published: April 2021

This research aimed at exploring the predictive value of 4-Hydroxyglutamate and miR-149-5p on eclampsia. Preeclampsia patients admitted to our hospital (n = 204), with 112 mild patients and 92 severe patients. Thereinto, pregnant women who underwent physical examination were regarded as a normal group (NG) (n = 100). Serum 4-Hydroxyglutamate levels and miR-149-5p in each group were detected. The serum 4-Hydroxyglutamate level in pregnant women in the NG was markedly lower than that in preeclampsia, while the miR-149-5p level was higher (p = 0.001). The serum 4-Hydroxyglutamate level in severe preeclampsia was higher than that in mild preeclampsia, while the miR-149-5p level was lower (p = 0.001). Partial thromboplastin time (APTT) and prothrombin time (PT) of preeclampsia patients were lower than those of the NG, while Fibrinogen (Fib) was higher (p = 0.001). With the aggravation of the condition of patients, PT, APTT decreased and Fib index increased. In preeclampsia patients, serum 4-Hydroxyglutamate was negatively correlated with PT and APTT, positively correlated with Fib content (p < 0.001); serum miR-149-5p was dramatically positively correlated with PT and APTT, negatively correlated with Fib content (p < 0.001). 4-Hydroxyglutamate and miR-149-5p were relevant to the occurrence time of preeclampsia; 4-Hydroxyglutamate, miR-149-5p and their combination could be used for preeclampsia diagnosis. According to the situation of newborn, they were divided into good and poor groups. The 4-Hydroxyglutamate level in the good group was lower than that in the poor group, while the miR-149-5p level was higher. The adverse prognosis of preeclampsia patients was predicted by 4-Hydroxyglutamate and miR-149-5p. 4-Hydroxyglutamate is highly expressed in preeclampsia, while miR-149-5p is low. Single and combined detection of 4-Hydroxyglutamate, miR-149-5p can be used for preeclampsia diagnosis and prediction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.yexmp.2021.104618DOI Listing

Publication Analysis

Top Keywords

serum 4-hydroxyglutamate
16
preeclampsia patients
12
predictive 4-hydroxyglutamate
8
4-hydroxyglutamate mir-149-5p
8
mir-149-5p eclampsia
8
pregnant women
8
4-hydroxyglutamate level
8
preeclampsia mir-149-5p
8
mir-149-5p level
8
higher p = 0001
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!