Objectives: Few data exist on perioperative three-dimensional-derived right ventricular strain. The authors aimed to describe the perioperative course of three-dimensional-derived right ventricular strain in coronary artery bypass graft (CABG) surgery patients.
Design: Prospective, observational, pilot trial.
Setting: Single university hospital.
Participants: The study comprised 40 patients with preserved left ventricular and right ventricular (RV) function undergoing isolated on-pump CABG surgery.
Interventions: Three-dimensional strain analysis and standard echocardiographic evaluation of RV function were performed preoperatively (T1) and postoperatively (T4) with transthoracic echocardiography (TTE) and intraoperatively before sternotomy (T2) and after sternotomy (T3) with transesophageal echocardiography (TEE). All echocardiographic measurements were performed under stable hemodynamic conditions and predefined fluid management without any vasoactive support.
Measurements And Main Results: The measurements of three-dimensional-derived RV free-wall strain (3D-RV FWS) and RV ejection fraction were performed using TomTec 4D RV-Function 2.0 software. Philips QLAB 10.8 was used to analyze tissue velocity of the tricuspid annulus, tricuspid annular systolic excursion, and RV fractional area change. There were no significant differences (median [interquartile range {IQR}]) between preoperative TTE and intraoperative TEE measurements for 3D-RV FWS (T1 v T2: -22.35 [IQR -17.70 to -27.22] v -24.35 [IQR -20.63 to -29.88]; not significant). 3D-RV FWS remained unchanged after sternotomy (T2 v T3: -24.35 [IQR -20.63 to -29.88] v -23.75 [IQR -20.25 to -29.28]; not significant) but deteriorated significantly after CABG (T1 v T4: -22.35 [IQR -17.70 to -27.22] v -18.5 [IQR -16.90 to -21.65]; p = 0.004).
Conclusion: In patients undergoing on-pump CABG, 3D-RV FWS values for awake, spontaneously breathing patients measured with TTE and values assessed in patients under general anesthesia with TEE did not significantly differ. Three-dimensional RV FWS did not change after sternotomy but deteriorated after on-pump CABG.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/j.jvca.2021.01.026 | DOI Listing |
Echocardiography
July 2023
Department of Cardiac Anesthesiology, Heart Center Dresden, University Hospital, Dresden, Germany.
Background: Data on intraoperative three-dimensionally derived right ventricular free-wall strain (3D-RV FWS) is sparse.
Objectives: We sought to evaluate the normal range of intraoperative 3D-RV FWS in patients scheduled for coronary artery bypass graft (CABG) surgery and compared to conventional echocardiographic parameters. Prospective observational study.
J Cardiothorac Vasc Anesth
June 2021
Department of Cardiac Anesthesiology, Heart Center Dresden, University Hospital, Dresden, Germany. Electronic address:
Objectives: Few data exist on perioperative three-dimensional-derived right ventricular strain. The authors aimed to describe the perioperative course of three-dimensional-derived right ventricular strain in coronary artery bypass graft (CABG) surgery patients.
Design: Prospective, observational, pilot trial.
J Cardiothorac Vasc Anesth
June 2019
Department of Anesthesiology, University of Utah, School of Medicine, Salt Lake City, UT.
Objective: To compare intraoperative right ventricular (RV) strain measurements made with left ventricular (LV) strain software commonly found on the echocardiography machine (Philips QLAB chamber motion quantification, version 10.7, Philips, Amsterdam, The Netherlands), with offline analysis using the dedicated RV strain software (EchoInsight, version 2.2.
View Article and Find Full Text PDFInt J Cardiol
December 2018
Department of Anesthesiology and Intensive Care Medicine, University Hospital Tübingen, Eberhard-Karls-University Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany.
Background: Right heart failure remains a major cause of morbidity and mortality after left ventricular assist device (LVAD) implantation. Multiple 2D echocardiography derived parameters are associated with right ventricular failure (RV failure), but none of them has been proven to be a reliable predictor to date. We hypothesized that novel 3D-echocardiography (3DE) based parameters are associated with RV failure and predict long term outcome in patients undergoing LVAD implantation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!