Six patients were found to have increased serum chloride concentrations when these concentrations were determined with an ion-selective electrode, but not when determined by continuous flow mercuric thiocyanate colorimetry or amperometric-coulometric titration. Their serum bromide levels of 1.8-8.0 mmol/l were much higher than those of 0.07-0.13 mmol/l in normal controls. The urinary bromide excretion, measured in two of these patients, was higher than that in normal subjects. No common symptoms or abnormalities in laboratory findings except hyperbromidaemia were found in these patients, who claimed not to have taken any drugs containing bromide. For determination of the incidence of subclinical hyperbromidaemia, the serum bromide concentrations were measured in sera of 1,323 outpatients sent to Tokushima University Hospital for routine measurements of blood chemistry over a one-month period. Five samples showed abnormally high bromide levels. It is concluded that subclinical hyperbromidaemia is not as rare as generally thought, though the aetiology of this state is unknown. Chloride determination with an ion-selective electrode can be used to screen for hyperbromidaemia, since increased levels of bromide ion result in apparently high chloride values.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00365518809085410DOI Listing

Publication Analysis

Top Keywords

ion-selective electrode
8
serum bromide
8
bromide levels
8
subclinical hyperbromidaemia
8
bromide
6
asymptomatic hyperbromidaemia
4
hyperbromidaemia detected
4
detected pseudohyperchloridaemia
4
pseudohyperchloridaemia measured
4
measured ion
4

Similar Publications

The development of a newly fabricated ion-selective electrode (ISE) solid-contacted type for the determination of prucalopride succinate represents a significant advancement in analytical chemistry, particularly in the context of green chemistry principles. The optimization process involved numerous trials to ensure the selection of a cation exchanger and ionophore that offer high sensitivity and selectivity for prucalopride succinate. Through these optimization trials, sodium tetrakis was identified as the most suitable cation exchanger, while calix [8] arene demonstrated the highest affinity towards prucalopride succinate as the ionophore.

View Article and Find Full Text PDF

As a hot issue, the scientific and effective separation and extraction of heavy metal ions from complex industrial effluent deserves wide investigation. Copper is an important valuable heavy metal in industrial wastewater. Selective extraction of copper ion (Cu) from effluent not only alleviates the shortage of resources, but also has economic and social benefits.

View Article and Find Full Text PDF

In this study, DL-phenylalanine modified with a multiwall carbon nanotube paste electrode is used as advanced electrochemical sensor for analysing of 0.1 mM caffeic acid (CFA) with simultaneous detection of riboflavin (RFN). The developed sensors include electrochemically polymerized DL-phenylalanine (DL-PA) modified multiwall carbon nanotube paste electrode [DL-PAMMCNTPE] and bare multiwall carbon nanotube paste electrode [BMCNTPE].

View Article and Find Full Text PDF

Biomimetic Plant-Root-Inspired Robotic Sensor System.

Biosensors (Basel)

November 2024

Nanobioengineering Group, Institute for Bioengineering of Catalonia (IBEC), Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, 08028 Barcelona, Spain.

There are many examples in nature in which the ability to detect is combined with decision-making, such as the basic survival instinct of plants and animals to search for food. We can technically translate this innate function via the use of robotics with integrated sensors and artificial intelligence. However, the integration of sensing capabilities into robotics has traditionally been neglected due to the significant associated technical challenges.

View Article and Find Full Text PDF

In recent years, wearable sweat sensors have garnered significant attention for real-time monitoring of human physiological information because of their ability to continuously and non-invasively detect multiple sweat biomarkers. Among these, potentiometric sensors stand out for their low power consumption, low cost, compact design, and real-time monitoring capabilities, making them an ideal alternative for sweat analysis. However, enhancing the sensitivity of ion-selective electrodes (ISEs), a critical parameter of potentiometric sensors, remains a challenging research focus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!