Objective: To examine and compare the accuracy of conventional radiography (CR) and musculoskeletal ultrasonography (US) in the diagnosis of calcium pyrophosphate (CPP) crystals deposition disease (CPPD).

Design: A systematic search of electronic databases (PubMed, Embase, and Cochrane), conference abstracts and reference lists was undertaken. Studies which evaluated the accuracy of CR and/or US in the diagnosis of CPPD, using synovial fluid analysis (SFA), histology or classification criteria as reference tests were included. Subgroup analyses by anatomic site and by reference test were performed.

Results: Twenty-six studies were included. Using SFA/histology as reference test, CR and US showed an excellent (CR AUC = 0.889, 95%CI = 0.811-0.967) and an outstanding (US AUC = 0.954, 95%CI = 0.907-1.0) diagnostic accuracy (p < 0.01), respectively. Furthermore, US showed a higher sensitivity (0.85, 95%CI = 0.79-0.90 vs 0.47, 95%CI = 0.40-0.55) and only a little lower specificity (0.87, 95%CI = 0.83-0.91 vs 0.95, 95%CI = 0.92-0.97) than CR. A considerable heterogeneity between the studies was found, with adopted reference test being the main source of heterogeneity. In fact, subgroup analysis showed a significant change in the diagnostic accuracy of CR, but not of US, using Ryan and McCarty criteria or SFA/histology as reference test (CR: AUC = 0.956, 95%CI = 0.925-1.0 vs AUC = 0.889, 95%CI = 0.828-0.950, respectively, p < 0.01) (US: AUC = 0.922, 95%CI = 0.842-1.0 vs AUC = 0.957, 95%CI = 0.865-1.0, respectively, p = 0.08) CONCLUSIONS: Although US is more sensitive and a little less specific than CR for identifying CPP crystals, both these two techniques showed a great diagnostic accuracy and should be regarded as complementary to each other in the diagnostic work-up of patients with CPPD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joca.2021.01.007DOI Listing

Publication Analysis

Top Keywords

conventional radiography
8
radiography musculoskeletal
8
musculoskeletal ultrasonography
8
calcium pyrophosphate
8
deposition disease
8
reference test
8
diagnostic conventional
4
ultrasonography calcium
4
pyrophosphate deposition
4
disease systematic
4

Similar Publications

Background: In uterine cervical cancer (UCC), tumour staging is performed according to the 2018 International Federation of Gynecology and Obstetrics (FIGO) system, where imaging is incorporated, or the more generic Tumour Node Metastasis (TNM) classification. With the technical development in diagnostic imaging, continuous prospective evaluation of the different imaging methods contributing to stage determination is warranted. The aims of this interim study were to (1) evaluate the performance of radiological FIGO (rFIGO) and T staging (rT) with 2-fluorine-18-fluoro-deoxy-glucose (2[18F]-FDG)-positron emission tomography with computed tomography (PET/CT) and with magnetic resonance imaging (PET/MRI), compared to clinical FIGO (cFIGO) and T (cT) staging based on clinical examination and conventional imaging, in treatment-naïve UCC, and to (2) identify possible MRI biomarkers for early treatment response after radiotherapy.

View Article and Find Full Text PDF

Introduction: Upper limb (UL) impairment is common in people with multiple sclerosis (pwMS), and functional recovery of the UL is a key rehabilitation goal. Technology-based approaches, like virtual reality (VR), are increasingly promising. While most VR environments are task-oriented, our clinical approach integrates neuroproprioceptive 'facilitation and inhibition' (NFI) principles.

View Article and Find Full Text PDF

Diagnostic Accuracy of Low-Dose Myocardial Perfusion Imaging in a Real-World Setting.

J Nucl Cardiol

January 2025

Université de Lorraine, CHRU-Nancy, Department of Nuclear Medicine and Nancyclotep Imaging Platform, F-54000, Nancy, France; Université de Lorraine, INSERM U1254, IADI, F-54000 Nancy, France. Electronic address:

Background: This large-scale study analyzes factors affecting diagnostic accuracy of low-dose myocardial perfusion imaging and correlation with coronary angiography in a real-world practice.

Methods: We compared data extracted from routine reports of (i) low-dose [Tc]sestamibi stress-MPI performed with no attenuation correction and predominantly exercise stress testing and (ii) the corresponding coronary angiography.

Results: We considered 1070 pairs of coronary angiography/stress-MPI results reported by 11 physicians.

View Article and Find Full Text PDF

Cross-sectional study on the impact of adverse childhood experiences on psychological distress in patients with an implantable cardioverter-defibrillator.

J Psychosom Res

January 2025

Department of Consultation-Liaison-Psychiatry and Psychosomatic Medicine, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland. Electronic address:

Objective: Previous studies implied detrimental effects of adverse childhood experiences (ACE) on cardiovascular disease and mental health. Still, data on the influence of ACE on psychological distress in patients with an implantable cardioverter-defibrillator (ICD) are lacking.

Methods: We prospectively recruited 423 patients with an ICD.

View Article and Find Full Text PDF

The central nervous system (CNS) tumor with embryonal tumors type is a rare type of CNS tumor with lack of unifying genetic alterations or diagnostic markers. The CNS tumor-embryonal tumors (CETs) have limited therapeutic options with high probability of adverse events associated with conventional treatment. Identification of somatostatin receptor expression and/or prostate-specific membrane antigen expression in CET patients by using PET/CT imaging may be helpful for deciding therapeutic approaches in these patients as theranostics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!