A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of different photoinitiators on the resistance of union in bovine dentin: Experimental and microscopic study. | LitMetric

Background: To evaluate the influence of photoinitiators on the microtensile strength of adhesive systems and composite resins in bovine dentin.

Material And Methods: Forty dentin obtained from bovine teeth were randomly distributed in four groups (n = 10) according to the different adhesive systems and composite resins used: G1 - AAPS + VAPS (Ambar APS + Vittra APS); G2- AAPS + O (Ambar APS + Opallis); G3 - A + VAPS (Ambar + Vittra APS) and G4 - A + O (Ambar + Opallis). After restoration with the composite, the samples were sectioned to obtain toothpicks that were subjected to the microtensile and nanofiltration test (1.0 mm/min).

Results: The Kruskal-Wallis test did not show significant differences between the groups (<0.05). The values in MPa were: AAPS + VAPS - 19.56 MPa; AAPS + O - 19.77 MPa; A + VAPS - 17.78 MPa; A + O - 22.44 MPa. The result of the Mann-Whitney test showed no significant differences depending on the adhesive (Ambar Universal- 19.11 MPa, Ambar APS Universal- 21.70 MPa) and the composite resin used (Vittra APS- 18.75 MPa, Opallis - 23.75 MPa). The AAPS + VAPS and AAPS + O groups showed intense silver nitrate infiltration. The A + APS group showed a moderate infiltration and the A + O group had a mild infiltration in the adhesive system/dentin interface.

Conclusions: The use of different photoinitiators in the composition of adhesive systems and restorative composites did not affect their bond strength values and the presence of water in the solvent of the APS photoinitiator system had a negative influence, increasing the degree of infiltration in the hybrid layer when compared to the camphorquinone photoinitiator. Dentin, adhesive systems, composite resin, photoinitiators, tensile strength, nano-infiltration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7864358PMC
http://dx.doi.org/10.4317/jced.57756DOI Listing

Publication Analysis

Top Keywords

influence photoinitiators
8
adhesive systems
8
systems composite
8
composite resins
8
vaps ambar
8
ambar aps
8
vittra aps
8
photoinitiators resistance
4
resistance union
4
union bovine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!