Objective: To investigate the measurement threshold of an intra-oral scanner (IOS) on polished human enamel.
Methods: The optical performance of an IOS was compared to a gold-standard non contacting laser profilometer (NCLP), on a painted microscope slide, compared to increasing particle size of silicon-carbide papers (21.8-269.0 μm) and separately on polished human enamel with increasing step-heights. The enamel samples were randomised (n = 80) and scanned using the IOS and NCLP at increasing step-height depths (μm) (1.87-86.46 μm) and quantified according to ISO:5436-1. The measurement threshold of the IOS was determined using a custom designed automated lesion localisation algorithm, corroborated by Gaussian skewness (Ssk) and kurtosis (Sku) analysis, to assess the minimum step-height measured on each enamel sample.
Results: The NCLP showed statistically increased Sq surface roughness for all silicon carbide particle sizes compared to the microscope slide, whereas, the IOS Sq roughness discriminated silicon-carbide particles above 68.0 μm compared to the glass slide (p ≤ 0.02). On polished enamel, the automated minimum detectable step-height measurable on each sample was 44 μm. No statistically significantly different step-height enamel lesion measurements were observed between NCLP and IOS above this threshold (p > 0.05).
Significance: This study revealed the fundamental optical metrological parameters for the IOS, was step-heights above 44 μm and this reflects the data acquisition of the system. These results highlight the limitations of IOS used in this study, mandating further research to optimise the performance of other IOS systems, for measuring wear of materials or tooth wear on human unpolished natural enamel surfaces.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.dental.2021.01.006 | DOI Listing |
Front Pediatr
January 2025
Gansu University of Chinese Medicine, Lanzhou, Gansu Province, China.
Background: Previous research has demonstrated that exposure to individual heavy metals elevates the incidence rate of congenital heart defects (CHDs). However, there is a paucity of data concerning the relationship between combined exposure to multiple heavy metals and the occurrence of CHDs. This study seeks to investigate the association between combined heavy metal exposure in pregnant women and the incidence of CHDs in their offspring in Lanzhou, China.
View Article and Find Full Text PDFJ Pain Res
January 2025
School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
Purpose: Complex regional pain syndrome (CRPS) is a debilitating chronic pain condition characterized by sensory, motor, and autonomic dysfunction with a world-wide prevalence of 26.2 per 100,000 people per year and is 3 to 4 times more prevalent in females. Repetitive transcranial magnetic stimulation (rTMS) has shown to be beneficial for pain relief in neuropathic pain and initial evidence in CRPS is promising, but studies are limited.
View Article and Find Full Text PDFFront Physiol
January 2025
Department of Sports, Physical Education and Outdoor Studies, University of South-Eastern Norway, Kongsberg, Norway.
Purpose: To explore the relationships between performance variables and physiological variables in a short-time (2-3 min) cycling time trial (TT) on a cycle ergometer.
Methods: Fifteen young elite cyclists (age: 17.3 ± 0.
Cureus
December 2024
Department of Breast, Plastic and Reconstructive Surgery, Royal Hallamshire Hospital, Sheffield, GBR.
Background The incidence of margin re-excision following breast conserving surgery (BCS) is a quality measure in the National Health Service. The threshold is less than 20% of all BCS procedures. Despite three decades of studies and a wealth of literature identifying multiple factors associated with increased risk for margin involvement, an accepted threshold rate affecting one in five procedures remains high.
View Article and Find Full Text PDFCureus
December 2024
Department of Health Sciences, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, JPN.
Purpose The infrapatellar fat pad (IFP) has the lowest pain threshold among all knee joint components and causes anterior knee pain after knee arthroplasty. It has been reported that selective muscle atrophy of the vastus medialis (VM) and fibrosis of the IFP may develop following knee joint surgery. Ultrasound enables visualization of IFP deformation (A1) from within the joint to the proximal area in response to muscle contraction, and this may be helpful in developing preventive and therapeutic strategies for IFP fibrosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!