Validity and reliability of smartphone applications for measurement of hip rotation, compared with three-dimensional motion analysis.

BMC Musculoskelet Disord

Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Prannok Road, Bangkok Noi, 10700, Bangkok, Thailand.

Published: February 2021

Background: Measurement of hip rotation is a crucial clinical parameter for the identification of hip problems and the monitoring of symptoms. The objective of this study was to determine whether the use of two smartphone applications is valid and reliable for the measurement of hip rotation.

Methods: An experimental, cross-sectional study was undertaken to assess passive hip internal and external rotation in three positions by two examiners. The hip rotational angles were measured by a smartphone clinometer application in the sitting and prone positions, and by a smartphone compass application in the supine position; their results were compared with those of the standard, three-dimensional, motion analysis system. The validities and inter-rater and intra-rater reliabilities of the smartphone applications were evaluated.

Results: The study involved 24 participants. The validities were good to excellent for the internal rotation angles in all positions (ICC 0.81-0.94), good for the external rotation angles in the prone position (ICC 0.79), and fair for the sitting and supine positions (ICC 0.70-0.73). The measurement of the hip internal rotation in the supine position had the highest ICC value of 0.94 (0.91, 0.96). The two smartphone applications showed good-to-excellent intra-rater reliability, but good-to-excellent inter-rater reliability for only three of the six positions (two other positions had fair reliability, while one position demonstrated poor reliability).

Conclusions: The two smartphone applications have good-to-excellent validity and intra-rater reliability, but only fair-to-good inter-rater reliability for the measurement of the hip rotational angle. The most valid hip rotational position in this study was the supine IR angle measurement, while the lowest validity was the ER angle measurement in the sitting position. The smartphone application is one of the practical measurements in hip rotational angles.

Trial Registration: Number 20181022003 at the Thai Clinical Trials Registry ( http://www.clinicaltrials.in.th ) which was retrospectively registered at 2018-10-18 15:30:29.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7879637PMC
http://dx.doi.org/10.1186/s12891-021-03995-2DOI Listing

Publication Analysis

Top Keywords

smartphone applications
20
measurement hip
20
hip rotational
16
hip
10
smartphone
8
hip rotation
8
three-dimensional motion
8
motion analysis
8
hip internal
8
external rotation
8

Similar Publications

In this research, we report a simple fluorescent probe designed to detect thallium(iii) ions (Tl) in artificial urine samples. The Tl signaling probe (TP-1) was readily prepared from 2-acetyl-6-methoxynaphthalene and hydrazine. In a pH 4.

View Article and Find Full Text PDF

Background And Aims: Studies using smartphone apps in treatment for alcohol dependence are lacking. This study aimed to test the consumption-reducing effects of using two app-based alcohol interventions as complement to treatment as usual (TAU).

Design: Three-armed, parallel, randomised controlled trial.

View Article and Find Full Text PDF

Background: Fully automated digital interventions delivered via smartphone apps have proven efficacious for a wide variety of mental health outcomes. An important aspect is that they are accessible at a low cost, thereby increasing their potential public impact and reducing disparities. However, a major challenge to their successful implementation is the phenomenon of users dropping out early.

View Article and Find Full Text PDF

Magnetofluidic-Assisted Portable Automated Microfluidic Devices for Protein Detection.

Anal Chem

January 2025

State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha 410082, China.

To facilitate on-site detection by nonspecialists, there is a demand for the development of portable "sample-to-answer" devices capable of executing all procedures in an automated or easy-to-operate manner. Here, we developed an automated detection device that integrated a magnetofluidic manipulation system and a signal acquisition system. Both systems were controllable via a smartphone.

View Article and Find Full Text PDF

Background: Nondaily smoking is a widespread and increasingly prevalent pattern of use. To date, no effective treatment approach for nondaily smoking has been identified.

Objective: This study aimed to conduct an unblinded randomized controlled trial to evaluate proof-of-concept markers of the Smiling instead of Smoking (SiS) app, a smartphone app for smoking cessation, designed specifically for people who smoke less than daily, within the framework of positive psychology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!