This work demonstrates the enhancement of the adsorption properties of polyethersulfone (PES) microfiltration membranes for 17β-estradiol (E2) from water. This compound represents a highly potent endocrine-disrupting chemical (EDC). The PES membranes were modified with a hydrophilic coating functionalized by amide groups. The modification was performed by the interfacial reaction between hexamethylenediamine (HMD) or piperazine (PIP) as the amine monomer and trimesoyl chloride (TMC) or adipoyl chloride (ADC) as the acid monomer on the surface of the membrane using electron beam irradiation. The modified membranes and the untreated PES membrane were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), water permeance measurements, water contact angle measurements, and adsorption experiments. Furthermore, the effects of simultaneous changes in four modification parameters: amine monomer types (HMD or PIP), acid monomer types (TMC or ADC), irradiation dosage (150 or 200 kGy), and the addition of toluene as a swelling agent, on the E2 adsorption capacity were investigated. The results showed that the adsorption capacities of modified PES membranes toward E2 are >60%, while the unmodified PES membrane had an adsorption capacity up to 30% for E2 under similar experimental conditions, i.e., an enhancement of a factor of 2. Next to the superior adsorption properties, the modified PES membranes maintain high water permeability and no pore blockage was observed. The highlighted results pave the way to develop efficient low-cost, stable, and high-performance adsorber membranes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911598 | PMC |
http://dx.doi.org/10.3390/membranes11020099 | DOI Listing |
PDA J Pharm Sci Technol
December 2024
Meissner Corporation.
FDA recommends monitoring differential pressure across filter membranes during sterile filtration process validation. However, few resources are available to help pharmaceutical manufacturers anticipate expected differential pressures during sterilizing filtration of different solutions. To address this gap, Meissner evaluated differential pressures across different filtration membranes using various test solutions at increasing pump speeds.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Environmental Engineering, Faculty of Engineering, Mersin University, 33343, Yenisehir, Mersin, Turkey.
Cerium oxide NPs (-CeO), with notable performance in various biological tests like redox activity, free radical scavenging, and biofilm inhibition, emerge as significant candidates to address issues in related areas. In this research, copper-decorated -CeO (Cu@-CeO) were first synthesized and then characterized using advanced techniques such as SEM-EDX, XRD, XPS, BET, and ICP-OES. The biochemical properties of the obtained Cu@-CeO nanostructure and its performance in polyethersulfone (PES) membranes were thoroughly investigated in this research study.
View Article and Find Full Text PDFLangmuir
December 2024
Centre for Research in Nanotechnology and Science, Indian Insitute of Technology Bombay, Mumbai 400076, India.
Emerging contaminants are a matter of growing concern for environmental and human health and safety, requiring efficient and affordable sensing platforms. Laser-induced graphene (LIG) is a novel material with a 3D porous graphene structure that can be fabricated in a simple one-step fabrication process. However, most LIG-based works in electrochemical sensors are limited to polyimide (PI)-based platforms, thus limiting the purview of properties of LIG dependent on the substrate-laser interaction.
View Article and Find Full Text PDFArtif Organs
December 2024
Department of Nephrology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Background: In cell-free and concentrated ascites reinfusion therapy (CART), filtration membrane obstruction during the ascites processing step is an important clinical problem. A novel membrane designed polyether sulfone filter (n-PES) was developed to reduce filter membrane obstruction. However, no clinical studies have compared the performance of n-PES filters with that of conventional filters.
View Article and Find Full Text PDFWater Res
December 2024
Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, 201210, China; University of Chinese Academy of Sciences, Beijing, 100049, China. Electronic address:
Micropollutants (MPs) in aquaculture water are directly related to human health, but largely overlooked. The conventional water treatment technologies could not effectively remove MPs, and new technologies have been pursued with high MP removal rate, low cost and small footprint. This paper reported the first endeavor of using layer-by-layer (LBL) hollow fiber (HF) nanofiltration (NF) membranes to treat real aquaculture water.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!