A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of LC-MS/MS method for the determination of UV-filters across human skin in vitro. | LitMetric

Development and validation of LC-MS/MS method for the determination of UV-filters across human skin in vitro.

J Chromatogr B Analyt Technol Biomed Life Sci

Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; BIOMIC_Auth, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, Buldings A&B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR-57001 Thessaloniki, Greece.

Published: March 2021

A novel High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) method was developed for the simultaneous determination of the in vitro skin permeation profile of four UV filters. The sunscreen products contained the following components: octocrylene (OC), ethylhexyl methoxycinnamate (EHMC), diethylamino hydroxybenzoyl hexyl benzonate (DHHB) and ethylhexyl salicylate (EHS). The target compounds were analyzed by HPLC-MS/MS method in positive ionization electrospray (ESI) in Multiple Reaction Monitoring (MRM) mode. The proposed method was validated in terms of the detection (LOD) and quantification limits (LOQ), linearity range, intra- and inter- day precision and accuracy of the analysis. The stability of the target compounds in solutions was also studied. All tests provided satisfactory results illustrating acceptable method performance. Samples were analyzed with simple pretreatment procedure, necessary to achieve solvent change and preconcentration. To evaluate matrix effect, the slopes of the standard regression curves with those of the matrix-matched calibration curves were compared using the Student's t-test. Quantitative evaluation of the test samples was performed using external methanolic calibration curves. Accuracy was found within the range 94.37-108.76%. The method was successfully applied to the analysis of UV filters in samples after permeability studies, in Franz's cells, for 24 h, using human skin. Concentration of sunscreens in the acceptor phase at the timescale of 24 h was very low implying the safety of the products.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2021.122561DOI Listing

Publication Analysis

Top Keywords

human skin
8
hplc-ms/ms method
8
target compounds
8
calibration curves
8
method
6
development validation
4
validation lc-ms/ms
4
lc-ms/ms method
4
method determination
4
determination uv-filters
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!