Purpose: To compare the accuracy of six intraoral scanners in two different partially edentulous maxillary models and to evaluate the effect of scanning sequence on accuracy.

Materials And Methods: Maxillary Kennedy Class I and Class IV situations were used as reference models. The reference datasets were obtained by scanning the models using a highly accurate industrial scanner (ATOS Core 80, GOM). The following six intraoral scanners were evaluated: Trios 3 (3Shape), iTero Element 2 (Align Technology), Emerald (Planmeca), CEREC Omnicam (Dentsply Sirona), CEREC Primescan (Dentsply Sirona), and Virtuo Vivo (Dental Wings). A total of 120 scans from both models were obtained using the six intraoral scanners and divided into two groups based on scanning sequence. Accuracy was evaluated by deviation analysis using 3D image processing software (Geomagic Studio 12, 3D Systems). Kruskal Wallis and Mann-Whitney U tests were performed (P ≤ .05) for statistical analysis.

Results: There were significant differences in the accuracy of digital impressions among intraoral scanners and scanning sequences. The trueness of the Trios scanner and the precision of the Trios, Primescan, and iTero scanners were significantly higher than for the other scanners. The Emerald had the lowest accuracy among the six intraoral scanners tested. Accuracy was affected by scanning sequence when using the Virtuo Vivo, Emerald, Primescan, and iTero.

Conclusion: In Kennedy Class I and Class IV partially edentulous cases, it is useful to consider that the intraoral scanner used may affect the accuracy of the digital impression.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.6834DOI Listing

Publication Analysis

Top Keywords

intraoral scanners
24
scanning sequence
16
accuracy digital
12
partially edentulous
12
digital impressions
8
impressions intraoral
8
scanners
8
scanners partially
8
accuracy intraoral
8
kennedy class
8

Similar Publications

Aims: To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.

View Article and Find Full Text PDF

Objective: This study aimed to compare the manufacturing accuracy of different printing techniques - Stereolithography (SLA), Digital Light Processing (DLP), and PolyJet-using digital dental models.

Methods: The study included cast models of 30 patients aged between 12 and 20 years. The selected models were scanned using an intraoral scanner, and surface topography format files were obtained.

View Article and Find Full Text PDF

Comparative evaluation of intraoral scanners and a spectrophotometer for percent correct shade identification in clinical dentistry.

Clin Oral Investig

January 2025

Center for Dental Medicine, Department of Operative Dentistry and Periodontology, Faculty of Medicine and Medical Center, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.

Objectives: The study aimed to assess the percent correct shade identification of four intraoral scanners (IOS) and a spectrophotometer, focusing on how reliably each device selects the correct tooth shade compared to a visual observer's selection. The research question addresses how much clinicians can trust the device-selected shade without visual verification.

Materials And Methods: Sixteen participants with natural, unrestored teeth were included.

View Article and Find Full Text PDF

Validation of a novel tool for automated tooth modelling by fusion of CBCT-derived roots with the respective IOS-derived crowns.

J Dent

December 2024

OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden. Electronic address:

Objectives: To validate a novel artificial intelligence (AI)-based tool for automated tooth modelling by fusing cone beam computed tomography (CBCT)-derived roots with corresponding intraoral scanner (IOS)-derived crowns.

Methods: A retrospective dataset of 30 patients, comprising 30 CBCT scans and 55 IOS dental arches, was used to evaluate the fusion model at full arch and single tooth levels. AI-fused models were compared with CBCT tooth segmentation using point-to-point surface distances-reported as median surface distance (MSD), root mean square distance (RMSD), and Hausdorff distance (HD)- alongside visual assessments.

View Article and Find Full Text PDF

Qualitative and quantitative assessment of tooth wear in young individuals.

J Dent

December 2024

Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Objectives: To assess the degree of tooth wear in children and adolescents by application of a qualitative wear index and by quantitative measurement on digital models. The hypothesis was that the quantitative method would be sensitive to reliably measure tooth wear.

Methods: Existing digital models (n = 24) gathered from a prospective clinical study were analysed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!