A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On the Consequences of Poorly Defined Breakpoints for Rifampin Susceptibility Testing of Mycobacterium tuberculosis Complex. | LitMetric

In a recent report of a systematic review of critical concentrations (CCs), the World Health Organization (WHO) lowered the rifampin (RIF) CC for antimicrobial susceptibility testing (AST) of the complex using Middlebrook 7H10 medium and the Bactec Mycobacterial Growth Indicator Tube (MGIT) 960 system from 1 to 0.5 μg/ml. The previous RIF CC for 7H10 had been in use for over half a century. Because it had served as the reference standard, it contributed to the endorsement of inappropriately high CCs for other AST methods, including the U.S. Food and Drug Administration (FDA)-approved MGIT system. Moreover, this resulted in confusion about the interpretation of seven borderline resistance mutations in (i.e., L430P, D435Y, H445L, H445N, H445S, L452P, and I491F). In this issue of the , Shea et al. (J Clin Microbiol 59:e01885-20, 2021, https://doi.org/10.1128/JCM.01885-20) provide evidence that the CC endorsed by the Clinical and Laboratory Standards Institute for the Sensititre MYCOTB system, which is not FDA approved but is CE-IVD marked in the European Union, is likely also too high. These findings underscore the importance of calibrating AST methods against a rigorously defined reference standard, as recently proposed by the European Committee on Antimicrobial Susceptibility Testing, as well as the value of routine next-generation sequencing for investigating discordant AST results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8092724PMC
http://dx.doi.org/10.1128/JCM.02328-20DOI Listing

Publication Analysis

Top Keywords

susceptibility testing
12
antimicrobial susceptibility
8
reference standard
8
ast methods
8
consequences defined
4
defined breakpoints
4
breakpoints rifampin
4
rifampin susceptibility
4
testing mycobacterium
4
mycobacterium tuberculosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!