A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anterograde and Retrograde Approach With Through-and-Through Wiring Technique to Treat a Ruptured and Extremely Tortuous Giant Popoliteal Artery Aneurism. | LitMetric

Purpose: This technical note aims to show a challenging endovascular treatment approach of a giant and tortuous ruptured popliteal artery aneurism.

Materials And Methods: An 86-year-old male patient was admitted for acute lower right limb ischemia. Angio-MSCT showed highly calcified superficial femoral artery, with a 180° bend in distal portion, followed by a large popliteal aneurism (63 × 61 mm) with a large extent hematoma (142 × 112 × 104 mm). Endovascular approach was chosen due to high morbidity.

Results: Anterior puncture of right superficial femoral artery was performed under ultrasound guidance. Despite various intents, the 0.035 hydrophilic coated wire could not be crossed distally through the aneurism. Retrograde access was performed via tibio-peroneal trunk under fluoroscopic guidance with a micropuncture set. A stiff 0.035″ Glidewire® was successfully advanced into the proximal portion of the aneurism through a 5F vertebral catheter externalized with a snare from the femoral sheath obtaining a "through-and-through wire" technique. Tightening of both ends of the wire helped gain support and straightened curves. Two stent grafts were implanted with no residual leak at 1 month follow-up.

Conclusion: Anterograde and retrograde approach was useful to perform a through-and-through wire technique in a challenging case of a tortuous ruptured popliteal artery aneurism.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1538574421993740DOI Listing

Publication Analysis

Top Keywords

anterograde retrograde
8
retrograde approach
8
artery aneurism
8
tortuous ruptured
8
ruptured popliteal
8
popliteal artery
8
superficial femoral
8
femoral artery
8
artery
5
aneurism
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!