While supine bioimpedance devices are used to evaluate for lymphedema (LE), stand-on devices are gaining popularity. Because research on differences in bioimpedance values between the two devices is limited, this study's purposes were to: (1) determine the average upper limb impedance values and inter-limb ratios for women who self-reported having ( = 34) or not having ( = 61) a history of LE, using a single-frequency supine device and a multifrequency stand-on device; (2) compare the level of agreement in inter-limb impedance ratios between the two devices; evaluate the percent agreement between the two devices in classifying cases of LE using established supine thresholds; and evaluate the percent agreement in classifying cases of LE between the supine device using previously established supine thresholds and the stand-on device using two published standing thresholds. Bioimpedance measures were done using the two devices. For the entire sample, absolute impedance values for both the affected and unaffected limbs were significantly higher for the stand-on device in women with and without LE. Impedance values for the two methods were highly correlated. Bland-Altman analysis determined that for the entire range of impedance ratios the values for the two devices could not be used interchangeably. Findings suggest that the stand-on device can be a useful and valid tool to assess for LE. However, because agreement is not perfect, values obtained from the two devices should not be used interchangeably to evaluate for changes in impedance ratios, particularly for ratios of >1.20.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792492 | PMC |
http://dx.doi.org/10.1089/lrb.2020.0058 | DOI Listing |
Front Digit Health
September 2024
Department of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education (MAHE), Manipal, India.
Introduction: An immobile patient cannot be weighed on a stand-on weighing machine, i.e., a bathroom scale.
View Article and Find Full Text PDFEur J Appl Physiol
September 2024
Institute for Active Health, Kyoto University of Advanced Science, Kyoto, Japan.
Purpose: Muscle quantity, defined as appendicular lean mass (ALM); muscle quality, defined as the ratio of muscle strength to ALM; and bioelectrical impedance analysis (BIA)-derived phase angle (PhA) are determinants of physical performance. We examined whether muscle quality indices were significant predictors of the whole-body reaction time (WBRT) in healthy female and male adults aged 20-91 years.
Methods: Data from 5164 adults (2869 women and 2295 men; mean age ± standard deviation, 60.
J Speech Lang Hear Res
August 2024
Department of Audiology, Hacettepe University, Ankara, Turkey.
Objective: The aim of this study was to investigate the effect of a visual cognitive additional task on balance performance in young adults with hearing aids (HAs).
Method: Twenty young adult HA users and 20 controls were recruited for the study. Participants were asked to stand on a force plate using computerized dynamic posturography and perform a Sensory Organization Test (SOT) as a balance task under single-task (ST) and dual-task (DT) conditions.
Technol Health Care
June 2024
Department of Biomedical Engineering, Konkuk University, Chungju, Korea.
Background: Studies investigating postural balance during various infant care postures have not been reported yet.
Objective: The aim of this study was to measure static postural balance when holding an infant dummy in-arms and carrying an infant dummy on back according to different infant dummy weights.
Methods: Sixteen healthy young subjects participated in a balance test.
Eur J Breast Health
April 2024
Australian Lymphoedema Education, Research and Treatment Centre, Department of Health Sciences, Faculty of Medicine, Health & Human Sciences, Macquarie University, Sydney, Australia.
Objective: Breast cancer related lymphedema (BCRL) may be assessed through objective measurement of limb swelling with common techniques including volumetric measurement using a tape measure or perometry, and measurement of extracellular water using bioimpedance spectroscopy (BIS). This study aimed to evaluate the performance of a stand-on BIS device for detection of BCRL, introduce a novel graphical method to compare volumetric and BIS methods alongside traditional specificity and sensitivity analysis, and determine and compare BIS thresholds with those published previously.
Materials And Methods: Female participants with indocyanine green lymphography confirmed unilateral arm lymphedema (n = 197) and healthy controls (n = 267) were assessed using a cross-sectional study design.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!