A correct use of inhaler devices is essential in chronic obstructive pulmonary disease (COPD) treatment. Critical errors were studied by analysing 659 video-recorded demonstrations of inhaler technique from 364 COPD patients using six different inhaler device models. The majority of the included patients used two (55%) or more (20%) device models. Overall, 66% of the patients made ≥1 critical error with at least one device model. The corresponding numbers for patients using 1, 2 and ≥3 device models were 43%, 70% and 86%, respectively. The only factor associated with making ≥1 critical error was simultaneous use of two (adjusted odds ratios (aOR) 3.17, 95% confidence interval (95% CI) 1.81, 5.64) or three or more (aOR 8.97, 95% CI 3.93, 22.1) device models. In conclusion, the proportion of patients making critical errors in inhaler technique was substantial, particularly in those using several different device models. To obtain optimal COPD treatment, it is important to assess a patient's inhaler technique and to minimise the number of inhaler device models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873256PMC
http://dx.doi.org/10.1038/s41533-021-00218-yDOI Listing

Publication Analysis

Top Keywords

device models
24
inhaler technique
16
video-recorded demonstrations
8
copd treatment
8
critical errors
8
inhaler device
8
≥1 critical
8
critical error
8
device
7
patients
6

Similar Publications

Photobiomodulation Combined With Human Umbilical Cord Mesenchymal Stem Cells Modulates the Polarization of Microglia.

J Biophotonics

January 2025

State Key Laboratory of Advanced Medical Materials and Devices, Tianjin Key Laboratory of Neuromodulation and Neurorepair, Integrative regeneration laboratory, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China.

Neuroinflammation plays a key role in the development of neurodegenerative diseases, with microglia regulating this process through pro-inflammatory M1 and anti-inflammatory M2 phenotypes. Studies have shown that human umbilical cord mesenchymal stem cells (hUCMSCs) modulate neuroinflammation by secreting anti-inflammatory cytokines. Photobiomodulation (PBM), a non-invasive therapy, has demonstrated significant potential in alleviating neuroinflammation.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the efficacy and safety of the Ahmed glaucoma valve in pediatric patients with refractory glaucoma.

Methods: A comprehensive literature search was conducted across multiple major databases, including PubMed, Embase, the Cochrane Library of Systematic Reviews, Science Direct, China's National Knowledge Infrastructure, and the Wanfang database. We retrieved studies published before December 2022 that met the inclusion criteria, including clinical controlled trials (randomized controlled trials) and clinical noncontrolled trials (non-randomized controlled trials) on the use of Ahmed glaucoma valve in pediatric patients with refractory glaucoma.

View Article and Find Full Text PDF

Gesture-controlled reconfigurable metasurface system based on surface electromyography for real-time electromagnetic wave manipulation.

Nanophotonics

January 2025

Key Laboratory for Information Science of Electromagnetic Waves, School of Information Science and Technology, Fudan University, Shanghai 200433, China.

Gesture recognition plays a significant role in human-machine interaction (HMI) system. This paper proposes a gesture-controlled reconfigurable metasurface system based on surface electromyography (sEMG) for real-time beam deflection and polarization conversion. By recognizing the sEMG signals of user gestures through a pre-trained convolutional neural network (CNN) model, the system dynamically modulates the metasurface, enabling precise control of the deflection direction and polarization state of electromagnetic waves.

View Article and Find Full Text PDF

Optical vortex beams carrying orbit angular momentum have attracted significant attention recently. Perfect vortex beams, characterized by their topological charge-independent intensity profile, have important applications in enhancing communication capacity and optimizing particle manipulation. In this paper, metal-insulator-metal copper-coin type reflective metasurfaces are proposed to generate perfect composite vortex beams in X-band.

View Article and Find Full Text PDF

Introduction: Accurate detection and recognition of tea bud images can drive advances in intelligent harvesting machinery for tea gardens and technology for tea bud pests and diseases. In order to realize the recognition and grading of tea buds in a complex multi-density tea garden environment.

Methods: This paper proposes an improved YOLOv7 object detection algorithm, called YOLOv7-DWS, which focuses on improving the accuracy of tea recognition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!