Background: In the modern western world appraisal of economical points such as treatment and disability after trauma present a financial burden. In this context open reduction internal fixation techniques allowing for early full weight bearing might not only improve the clinical outcome but also shorten the period of disability in working life. The aim of the study was to analyze whether ORIF of ankle fractures using either a standard semitubular plate or a new polyaxial locking plate system result in a better clinical outcome.

Methods: In this prospective study, all patients with distal fibula fractures (AO 44 B1.1, B1.2, B1.3), with indication for surgery were included. Patients were randomized to either the DePuy Synthes® one-third semitubular plate (Group I) or NEWCLIP TECHNICS, Active Ankle® polyaxial locking plate (Group II). Primary outcome parameter was function of the ankle joint, assessed by the Olerud and Molander ankle score, Foot and Ankle outcome score and Karlsson and Peterson Scoring System for Ankle function. Secondary outcome parameter were postoperative complications. Superficial wound infection, delayed wound healing, mechanically prominent implant, skin irritations were considered as minor and deep wound infection, material loosening, loss of reduction were regarded as major complications requiring revision surgery. Clinical and radiological follow-up were performed 6 and 12 weeks, 6 months and 1 year postoperatively.

Results: Fifty-two patients (31 W/21 M) with a mean age of 43 yrs. (range 22-64 yrs.) were enrolled. Seven patients (13.5%) were excluded, so that 45 patients were available for follow up. Twenty-five patients were treated with DePuy Synthes® one-third semitubular plate (55.6%; group I) while 20 patients received an anatomically preformed polyaxial locking plate (44.4%, group II). Four minor complications occurred in Group I (16%) compared to two minor complications in group II (10%). Significant better clinical results regarding OMAS (p < 0.02, < 0.04), KPSS (p < 0.04) and FAOS (p < 0.02, < 0.03) were observed 6 and 12 weeks after surgery in group II.

Conclusions: The results of the presented study demonstrate a significant better clinical functional outcome in the early postoperative follow-up in patients treated with a polyaxial locking plate. Furthermore, our data show that ORIF using polyaxial locking plates in combination with an early postoperative weight bearing presents a safe, stable treatment option for ankle fractures so that patients benefit especially in the early stages of recovery.

Trial Registration: Registered 20 April 2020, retrospectively on ClinicalTrails.gov ( NCT04370561 ).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7874601PMC
http://dx.doi.org/10.1186/s12891-021-04009-xDOI Listing

Publication Analysis

Top Keywords

locking plate
16
semitubular plate
12
polyaxial locking
12
early full
8
full weight
8
weight bearing
8
distal fibula
8
better clinical
8
depuy synthes®
8
synthes® one-third
8

Similar Publications

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Risk factors for complications following volar locking plate fixation of distal radial fractures.

Orthop Traumatol Surg Res

December 2024

Service de Chirurgie Orthopédique et Traumatologique, Hôpital de la Cavale Blanche, Boulevard Tanguy Prigent, Brest 29200, France; Université de Bretagne Occidentale, UBO, Brest 29200, France; LaTIM, INSERM, UMR 1101, SFR IBSAM, Avenue Foch, Brest 29200, France. Electronic address:

Article Synopsis
  • The study focuses on distal radial fractures and the complications associated with volar locking plate (VLP) fixation, which can lead to implant removal.
  • Researchers analyzed data from 2951 patients, identifying intrinsic (like age and fracture type) and extrinsic (such as plate positioning) risk factors for complications post-fixation.
  • Key findings revealed that being under 62 years old, having a specific type of fracture, and the plate's positioning were significant risk factors for complications that might necessitate implant removal.
View Article and Find Full Text PDF

Functional Outcome of Subtrochanteric Femoral Fractures Fixation by Proximal Femoral Locking Compression Plate.

Mymensingh Med J

January 2025

Dr Md Sonaullah, Assistant Professor, Department of Orthopedics and Traumatology, Mymensingh Medical College (MMC), Mymensingh, Bangladesh; E-mail:

Subtrochanteric femoral fractures are one of the common fractures encountered in today's Orthopaedic practice. This area consists of mostly cortical bone with high stress generation thus heal slowly which leads implant failure. The inherent instability of this fracture and forces of the muscles with comminuted medial calcar is giving the fracture a tendency to varus collapse.

View Article and Find Full Text PDF

In this report, we present a case of a triple clavicle injury, acromioclavicular joint (ACJ) dislocation, a middle third clavicle fracture, and a sternoclavicular joint (SCJ) subluxation, and describe its successful surgical treatment. A 49-year-old female patient sustained a 3 m fall, resulting in direct trauma to her left shoulder. Initial radiographs and computed tomography (CT) scans revealed a displaced middle third clavicle fracture, a high-grade ACJ dislocation, and a posterior SCJ subluxation.

View Article and Find Full Text PDF

Background: The purpose of this study was to report the clinical and psychological outcomes of using a locking compression plate (LCP) as a sequential external fixator following the distraction phase in the treatment of tibial bone defects caused by fracture-related infection (FRI).

Methods: We retrospectively analyzed the clinical records and consecutive X-ray images of patients with tibial bone defects who were treated with an LCP as a sequential external fixator following the distraction phase, between June 2017 and December 2022. The ASAMI criteria were applied to assess the bone and functional outcomes, and postoperative complications were evaluated by using the Paley classification.

View Article and Find Full Text PDF