Sensory feedback from wearables can be effective to learn better movement through enhanced information and engagement. Facilitating greater user cognition during movement practice is critical to accelerate gains in motor function during rehabilitation following brain or spinal cord trauma. This preliminary study presents an approach using an instrumented glove to leverage sense of agency, or perception of control, to provide training feedback for functional grasp. Seventeen able-bodied subjects underwent training and testing with a custom-built sensor glove prototype from our laboratory. The glove utilizes onboard force and flex sensors to provide inputs to an artificial neural network that predicts achievement of "secure" grasp. Onboard visual and audio feedback was provided during training with progressively shorter time delay to induce greater agency by intentional binding, or perceived compression in time between an action (grasp) and sensory consequence (feedback). After training, subjects demonstrated a significant reduction ( < 0.05) in movement pathlength and completion time for a functional task involving grasp-move-place of a small object. Future work will include a model-based algorithm to compute secure grasp, virtual reality immersion, and testing with clinical populations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915039 | PMC |
http://dx.doi.org/10.3390/s21041173 | DOI Listing |
Sci Rep
January 2025
Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Intramedullary nail fixation is a routine procedure for treatment of intertrochanteric fractures. Aseptic technique is vital for reducing postoperative complications, as intraoperative glove perforations increase the risk of surgical site infections. The aim of this study was to determine the incidence of surgical glove perforation during intramedullary nailing of intertrochanteric fractures and to identify surgery-specific steps at risk.
View Article and Find Full Text PDFCurr Opin Cardiol
December 2024
Division of Cardiac Surgery, St. Michael's Hospital, University of Toronto, Toronto, Ontario.
ACS Appl Mater Interfaces
January 2025
National Engineering Lab of Special Display Technology, Special Display and Imaging Technology Innovation Center of Anhui Province, Academy of Optoelectronic Technology, Hefei University of Technology, Hefei 230009, China.
Flexible sensors mimic the sensing ability of human skin, and have unique flexibility and adaptability, allowing users to interact with intelligent systems in a more natural and intimate way. To overcome the issues of low sensitivity and limited operating range of flexible strain sensors, this study presents a highly innovative preparation method to develop a conductive elastomeric sensor with a cracked thin film by combining polydimethylsiloxane (PDMS) with multiwalled carbon nanotubes (MCNT). This novel design significantly increases both the sensitivity and operating range of the sensor (strain range 0-50%; the maximum tensile sensitivity of this sensor reaches 4.
View Article and Find Full Text PDFSurg Endosc
December 2024
Division of Gastrointestinal and Minimally Invasive Surgery, Department of Surgery, Carolinas Medical Center, Charlotte, NC, USA.
Introduction: Wound complications (WC) after abdominal wall reconstruction (AWR) are associated with increased cost, recurrence, and mesh infection. Operative closing protocols (CP) have been studied in other surgical disciplines but not in AWR. Our aim was to study the effect of a CP on WC after AWR.
View Article and Find Full Text PDFFront Surg
November 2024
Department of Anesthesiology, The Fourth Medical Center of the PLA General Hospital, Beijing, China.
Background: Infection is a devasting complication after arthroplasty. Identifying potential sources contributing to intraoperative bacterial transmission can help to reduce surgical-site infections.
Objective: The aim of this study was to identify the incidence and risk factors of intraoperative bacterial contamination (IBC) in primary total knee arthroplasty (TKA) procedures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!