Computer-aided Detection of Subsolid Nodules at Chest CT: Improved Performance with Deep Learning-based CT Section Thickness Reduction.

Radiology

From the Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 138-736, Korea (S.P., S.M.L., W.K., K.H.D., J.B.S.); and VUNO, Seoul, South Korea (H.P., K.H.J.).

Published: April 2021

Background Studies on the optimal CT section thickness for detecting subsolid nodules (SSNs) with computer-aided detection (CAD) are lacking. Purpose To assess the effect of CT section thickness on CAD performance in the detection of SSNs and to investigate whether deep learning-based super-resolution algorithms for reducing CT section thickness can improve performance. Materials and Methods CT images obtained with 1-, 3-, and 5-mm-thick sections were obtained in patients who underwent surgery between March 2018 and December 2018. Patients with resected synchronous SSNs and those without SSNs (negative controls) were retrospectively evaluated. The SSNs, which ranged from 6 to 30 mm, were labeled ground-truth lesions. A deep learning-based CAD system was applied to SSN detection on CT images of each section thickness and those converted from 3- and 5-mm section thickness into 1-mm section thickness by using the super-resolution algorithm. The CAD performance on each section thickness was evaluated and compared by using the jackknife alternative free response receiver operating characteristic figure of merit. Results A total of 308 patients (mean age ± standard deviation, 62 years ± 10; 183 women) with 424 SSNs (310 part-solid and 114 nonsolid nodules) and 182 patients without SSNs (mean age, 65 years ± 10; 97 men) were evaluated. The figures of merit differed across the three section thicknesses (0.92, 0.90, and 0.89 for 1, 3, and 5 mm, respectively; = .04) and between 1- and 5-mm sections ( = .04). The figures of merit varied for nonsolid nodules (0.78, 0.72, and 0.66 for 1, 3, and 5 mm, respectively; < .001) but not for part-solid nodules (range, 0.93-0.94; = .76). The super-resolution algorithm improved CAD sensitivity on 3- and 5-mm-thick sections ( = .02 for 3 mm, < .001 for 5 mm). Conclusion Computer-aided detection (CAD) of subsolid nodules performed better at 1-mm section thickness CT than at 3- and 5-mm section thickness CT, particularly with nonsolid nodules. Application of a super-resolution algorithm improved the sensitivity of CAD at 3- and 5-mm section thickness CT. © RSNA, 2021 See also the editorial by Goo in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2021203387DOI Listing

Publication Analysis

Top Keywords

computer-aided detection
12
subsolid nodules
12
deep learning-based
12
5-mm thickness
12
super-resolution algorithm
12
nonsolid nodules
12
thickness
11
detection cad
8
cad performance
8
5-mm-thick sections
8

Similar Publications

This study introduces a novel deep learning approach for 3D teeth scan segmentation and labeling, designed to enhance accuracy in computer-aided design (CAD) systems. Our method is organized into three key stages: coarse localization, fine teeth segmentation, and labeling. In the teeth localization stage, we employ a Mask-RCNN model to detect teeth in a rendered three-channel 2D representation of the input scan.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the hydrolytic behavior of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin matrix ceramics (RMCs) in different food-simulating liquids (FSLs).

Materials And Methods: Five different CAD/CAM blocks, one from polymer-infiltrated ceramic networks (PICNs; Vita Enamic (EN)) and four from resin-based composites (RBCs; Lava Ultimate (UL), Cerasmart (CER), Brilliant Crios (BR), and Block HC (HC)) were selected. Forty specimens were prepared for each material, and they randomly distributed to each FSLs.

View Article and Find Full Text PDF

Image processing and pattern recognition methods have recently been extensively implemented in histopathological images (HIs). These computer-aided techniques are aimed at detecting the attentive biological markers for assisting the final cancer grading. Mitotic count (MC) is a significant cancer detection and grading parameter.

View Article and Find Full Text PDF

Background: Efforts to improve colonoscopy have recently focused on improving adenoma detection through individual interventions. We evaluated an optimized computer-assisted technique (CADopt) versus standard colonoscopy.

Methods: A prospective randomized controlled trial was conducted enrolling adults (45-80 years) undergoing elective colonoscopy.

View Article and Find Full Text PDF

A prospective comparison of two computer aided detection systems with different false positive rates in colonoscopy.

NPJ Digit Med

December 2024

Department of Internal Medicine and Healthcare Research Institute, Healthcare System Gangnam Center, Seoul National University Hospital, Seoul, Korea.

This study evaluated the impact of differing false positive (FP) rates in two computer-aided detection (CADe) systems on the clinical effectiveness of artificial intelligence (AI)-assisted colonoscopy. The primary outcomes were adenoma detection rate (ADR) and adenomas per colonoscopy (APC). The ADR in the control, system A (3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!