Temporal and seasonal variations of noise pollution in urban zones: a case study in Pakistan.

Environ Sci Pollut Res Int

Department of Environmental Sciences, Fatima Jinnah Women University, Mall Road, Rawalpindi, Pakistan.

Published: June 2021

Noise pollution is widely recognized as an important problem and can negatively affect quality of life. This study aimed to examine the temporal and seasonal variations of noise pollution in urban zones of Peshawar, Pakistan. This city is increasingly becoming congested and traffic-related problems are common. Noise levels were assessed in four different seasons at 20 points around the city, including three different zones: commercial, residential, and silent. All the noise indices including equivalent noise level, day and night time noise level, noise climate, and noise pollution level were calculated for all zones. In winter, the Leq values ranged between 52.5 and 73.3 dBA; while in spring, summer, and autumn, it ranged between 56.2 and 88.3 dBA; 46.9 and 88.6 dBA; and 49.2 and 76.6 dBA, respectively. The level of the noise was observed highest in commercial followed by residential and the silent zones. The levels of the noise were beyond the permissible limits in some zones mentioned in the Pakistan National Environmental Quality Standards (Pak-NEQS' 2010). The seasonal variation in Leq revealed that the noise level in 70% of areas increased from winter to spring, 45% from spring to summer, 35% summer to autumn, 30% autumn to winter, 70% winter to summer, and 40% spring to autumn. Temperature, humidity, and wind speed were the main seasonal factors causing the seasonal variations and traffic was the main source of noise pollution identified in the area.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-021-12738-8DOI Listing

Publication Analysis

Top Keywords

noise pollution
20
noise
13
seasonal variations
12
noise level
12
temporal seasonal
8
variations noise
8
pollution urban
8
urban zones
8
commercial residential
8
residential silent
8

Similar Publications

Hyperbaric oxygen therapy and corticosteroids as combined treatment for acute acoustic trauma.

Eur Arch Otorhinolaryngol

January 2025

Motion Sickness and Human Performance Laboratory, The Israel Naval Medical Institute, IDF Medical Corps, Haifa, Israel.

Purpose: Acute acoustic trauma (AAT) is a sudden sensorineural hearing loss (SNHL) due to exposure to high intensity impulse noise. There are no acceptable treatment guidelines, although several studies showed steroids could be effective in restoring hearing levels. A recent report suggested that steroids combined with hyperbaric oxygen therapy (HBOT) are a superior regiment for AAT.

View Article and Find Full Text PDF

Diabetes is a growing health concern in developing countries, causing considerable mortality rates. While machine learning (ML) approaches have been widely used to improve early detection and treatment, several studies have shown low classification accuracies due to overfitting, underfitting, and data noise. This research employs parallel and sequential ensemble ML approaches paired with feature selection techniques to boost classification accuracy.

View Article and Find Full Text PDF

Ultrasound is a primary diagnostic tool commonly used to evaluate internal body structures, including organs, blood vessels, the musculoskeletal system, and fetal development. Due to challenges such as operator dependence, noise, limited field of view, difficulty in imaging through bone and air, and variability across different systems, diagnosing abnormalities in ultrasound images is particularly challenging for less experienced clinicians. The development of artificial intelligence (AI) technology could assist in the diagnosis of ultrasound images.

View Article and Find Full Text PDF

Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.

View Article and Find Full Text PDF

Quantitative and Visual Benefits of Data-Driven Motion Correction on Oncologic PET/CT: A Prospective Cross-sectional Study.

Acad Radiol

January 2025

Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:

Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!