A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Self-made wire-rope button plate: A novel option for the treatment of distal tibiofibular syndesmosis separation. | LitMetric

Objective: To compare the clinical effect of the self-made wire-rope button plate and cortical screw in the treatment of the distal tibiofibular syndesmosis separation.

Methods: Total 26 patients with distal tibiofibular syndesmosis separation were treated with internal fixation with a self-made wire-rope button plate and cortical screw. They were divided into a self-made wire-rope button plate group and cortical screw group. self-made wire-rope button plate group: 12 cases of inferior tibiofibular syndesmosis were reconstructed by self-made wire-rope button plate. Cortical screw group: 14 cases of inferior tibiofibular syndesmosis were reconstructed by cortical screw. The follow-up data of 2, 6, 12 weeks and 6 and 12 months after operation were collected.

Results: There was no significant difference in operative time, the amount of intraoperative bleeding and postoperative complications between the two groups (P > 0.05). Comparison of postoperative complications: There was no loosening and rupturing of internal fixation in the self-made wire-rope button plate group. In the cortical screw group, the rupture of screws was found in 1 case, which occurred in the 10th weeks after the operation, and the broken screws were removed after 1 year with other internal fixations. Within 12 weeks of reoperation to remove the internal fixation rate: There was a significant difference in the rate of reoperation to remove the internal fixation within 12 weeks (p < 0.05). At the last follow-up, the AOFAS score of the ankle joint were 94 ± 4.79 in the self-made wire-rope button plate group and 92.8 ± 6.73 in the cortical screw group. There was no significant difference (P > 0. 05).

Conclusion: The self-made wire-rope button plate and cortical screw can effectively treat the separation of the tibiofibular syndesmosis. It provides a new choice for the treatment of inferior tibiofibular syndesmosis.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2309499020975215DOI Listing

Publication Analysis

Top Keywords

self-made wire-rope
36
wire-rope button
36
button plate
36
cortical screw
32
tibiofibular syndesmosis
28
plate cortical
16
internal fixation
16
plate group
16
screw group
16
distal tibiofibular
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!