Ultrasensitive PCR used in low-transmission malaria-endemic settings has revealed a much higher burden of asymptomatic infections than that detected by rapid diagnostic tests (RDTs) or standard PCR, but there is limited evidence as to whether this is the case in higher transmission settings. Using dried blood spots (DBS) collected among 319 schoolchildren in Bagamoyo, Tanzania, we found good correlation (Pearson's R = 0.995) between Plasmodium falciparum parasite densities detected by a DNA-based 18s rRNA real-time PCR (qPCR) and an RNA-based ultrasensitive reverse transcriptase (RT)-PCR (usPCR) for the same target. Whereas prevalence by usPCR was higher than that found by qPCR (37% versus 32%), the proportion of additionally detected low-density infections (median parasite density < 0.050 parasites/µL) represented an incremental increase. It remains unclear to what extent these low-density infections may contribute to the infectious reservoir in different malaria transmission settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8045654PMC
http://dx.doi.org/10.4269/ajtmh.20-1233DOI Listing

Publication Analysis

Top Keywords

ultrasensitive pcr
8
plasmodium falciparum
8
dried blood
8
blood spots
8
bagamoyo tanzania
8
transmission settings
8
low-density infections
8
direct comparison
4
comparison standard
4
standard ultrasensitive
4

Similar Publications

Enhancing early breast cancer detection with APE1-triggered oligonucleotide probes and graphene oxide: The impact of variable AP site modification on sensitivity and specificity.

Talanta

January 2025

Guangdong Provincial Key Laboratory of New Drug Screening, Guangzhou Key Laboratory of Drug Research for Emerging Virus Prevention and Treatment, NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, Guangdong-Hong Kong-Macao Joint Laboratory for New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, Guangzhou, Guangdong, 510515, China. Electronic address:

There is a critical need for inclusive diagnostic platforms to enhance the accuracy of early breast cancer detection. Dysregulated microRNA-1246 (miR-1246), closely linked to the disease progression and recurrence, has emerged as a promising diagnostic and prognostic biomarker for BC. However, achieving simple, rapid, and ultrasensitive quantification of serum miRNAs remains significant challenge.

View Article and Find Full Text PDF

Ultra-Sensitive Aptamer-Based Diagnostic Systems for Rapid Detection of All SARS-CoV-2 Variants.

Int J Mol Sci

January 2025

Department of Life Sciences, POSTECH Biotech Center, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang-si 37673, Republic of Korea.

The emergence of numerous SARS-CoV-2 variants, characterized by mutations in the viral RNA genome and target proteins, has presented challenges for accurate COVID-19 diagnosis. To address this, we developed universal aptamer probes capable of binding to the spike proteins of SARS-CoV-2 variants, including highly mutated strains like Omicron. These aptamers were identified through protein-based SELEX using spike proteins from three key variants (D614G-substituted Wuhan-Hu-1, Delta, and Omicron) and virus-based SELEX, known as viro-SELEX.

View Article and Find Full Text PDF

Introduction: Recently, efforts to eliminate malaria have shifted focus from symptomatic cases alone to include asymptomatic carriers, who are now recognized as significant contributors to the disease's transmission and control. This study examines the relationship between asymptomatic malaria infection and hemoglobin levels in Benin.

Methods: A cohort in Benin was enrolled and categorized into three age groups (under 5 years, 5-15 years, and over 15 years) for follow-up from August to November 2021.

View Article and Find Full Text PDF

Background: Covalently closed circular DNA (cccDNA) is a stable, episomal form of HBV DNA. cccDNA is a true marker for the intrahepatic events in controlled CHB infection. Quantifying cccDNA is critical for monitoring disease progression, and efficacy of anti-viral therapies.

View Article and Find Full Text PDF

Phage-ELISA for ultrasensitive detection of .

Analyst

January 2025

College of Veterinary Medicine, Institute of Comparative Medicine, Yangzhou University, Yangzhou 225009, China.

The M13 phage carries approximately 5 copies of the pIII protein, each of which is capable of displaying a single-chain variable fragment (scFv) that targets a specific antigen. This feature enables the M13 phage to be widely employed in the construction of scFv libraries, thereby facilitating the identification of antibodies with high specificity and affinity for target antigens. In this study, mice were immunized three times with (strain C50041) to induce diverse antibodies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!