A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring for central apnoea in infancy--limitations of single channel recordings. | LitMetric

Apparent central apnoea (absent breathing movements) detected by monitoring movement of the thoracic wall was compared with simultaneous detection by abdominal wall movement. Eighteen infants provided one or more 24 hour recording of heart rate (electrocardiography), thoracic respiration (transthoracic impedance), and abdominal wall movement (pressure sensitive capsule distortion). Detection of true apnoea, recognition of artefact, and measurement of the duration of true apnoea were all improved when two channels of respiratory monitoring were used in combination. We recommend that any study purporting to observe breathing patterns by indirect recording of respiratory movement will be more reliable if more than one channel of respiratory movements is recorded simultaneously. Further, in infants no estimation of duration of central apnoea can be made on the basis of either a transthoracic impedance record alone or an abdominal wall movement sensor alone. Comparison of findings among studies using different single channel recordings are unlikely to be meaningful.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1778760PMC
http://dx.doi.org/10.1136/adc.63.3.282DOI Listing

Publication Analysis

Top Keywords

central apnoea
12
abdominal wall
12
wall movement
12
single channel
8
channel recordings
8
transthoracic impedance
8
true apnoea
8
apnoea
5
movement
5
monitoring central
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!