The identification of gastrointestinal (GI) motility disorders requires the evaluation of regional GI transit, and the development of alternative methodologies in animals has a significant impact on translational approaches. Therefore, the purpose of this study was to validate an easy and low-cost methodology (alternate current biosusceptometry - ACB) for the assessment of regional GI transit in rats through images. Rats were fed a test meal containing magnetic tracer and phenol red, and GI segments (stomach, proximal, medial and distal small intestine, and cecum) were collected to assess tracer's retention at distinct times after ingestion (0, 60, 120, 240, and 360 min). Images were obtained by scanning the segments, and phenol red concentration was determined by the sample's absorbance. The temporal retention profile, geometric center, gastric emptying, and cecum arrival were evaluated. The correlation coefficient between methods was 0.802, and the temporal retention of each segment was successfully assessed. GI parameters yielded comparable results between methods, and ACB images presented advantages as the possibility to visualize intrasegmental tracer distribution and the automated scan of the segments. The imaging approach provided a reliable assessment of several parameters simultaneously and may serve as an accurate and sensitive approach for regional GI research in rats.

Download full-text PDF

Source
http://dx.doi.org/10.1515/bmt-2020-0202DOI Listing

Publication Analysis

Top Keywords

easy low-cost
8
transit rats
8
regional transit
8
phenol red
8
temporal retention
8
low-cost biomagnetic
4
biomagnetic methodology
4
methodology study
4
regional
4
study regional
4

Similar Publications

Unlabelled: Early detection of Autism is a challenge in Chile and Latin America. Gold-standard evaluations are expensive and difficult to access. The Autism Mental Status Exam (AMSE) is a brief, structured, observational instrument for clinical use with promising results.

View Article and Find Full Text PDF

A POCT assay based on commercial HCG strip for miRNA21 detection by integrating with RCA-HCR cascade amplification and CRISPR/Cas12a.

Mikrochim Acta

January 2025

Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China.

A point-of-care testing (POCT) assay based on commercial HCG strip was proposed for miRNA21 detection by integrating RCA-HCR cascaded isothermal amplification with CRISPR/Cas12a. Three modules were integrated in the proposed platform: target amplification module composed of rolling circle amplification (RCA) cascaded with hybridization chain reaction (HCR), signal transduction module composed of CRISPR/Cas12a combined with HCG-agarose gel beads probes, and signal readout module composed of commercial HCG strips. The proposed RCA-HCR-CRISPR/Cas12a-HCG strip assay for miRNA21 detection had high sensitivity, and the limit of detection was as low as 37 fM.

View Article and Find Full Text PDF

N-oxide-Functionalized Bipyridines as Strong Electron-Deficient Units to Construct High-Performance n-Type Conjugated Polymers.

Adv Sci (Weinh)

January 2025

Key Laboratory of Functional Molecular Solids, Ministry of Education, School of Chemistry and Materials Science, Anhui Normal University, No.189, Jiuhua South Road, Wuhu, Anhui, 241002, China.

Developing low-cost unipolar n-type organic thin-film transistors (OTFTs) is necessary for logic circuits. To achieve this objective, the usage of new electron-deficient building blocks with simple structure and easy synthetic route is desirable. Among all electron-deficient building units, N-oxide-functionalized bipyridines can be prepared through a simple oxidized transformation of bipyridines.

View Article and Find Full Text PDF

A Novel Self-Opening Transfer Shuttle for the Transfer of Air-Sensitive Sample to Scanning Electron Microscopy.

Microsc Microanal

January 2025

Instrumental Analysis Center, Dalian University of Technology, No.2 Linggong Road, Ganjingzi District, Dalian, Liaoning Province 116024, China.

A self-opening transfer shuttle has been designed and fabricated for the transfer of air-sensitive samples to scanning electron microscopy (SEM). Delayed push out of an airtight sample cabin sealed inside the shuttle allows the protection of the sample from air exposure during the pumping of SEM chamber. A compressed spring is employed to automatically drive the push out of the cabin.

View Article and Find Full Text PDF

Introduction: Pressure injuries (PIs) continue to remain one of the most common and debilitating complications seen adding to the financial burden of the patients and caregivers. The available VAC (vacuum assisted closure) systems are expensive. In our case series we have applied low-cost negative pressure dressing (NPD) for sacral pressure injuries in five patients along with individualised rehabilitation protocol which resulted in accelerated healing of their PIs and improved functional outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!