Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Brain parenchyma retraction is often necessary to reach various deep brain lesions during surgery. In order to minimise the incidence of the brain retraction injury, an endoport system may be employed. We present a report of a navigated endoport system in conjunction with an purely endoscopic microsurgery that was used in a patient with a deep-seated subependymoma.
Case Report: A navigated endoport with purely endoscopic microsurgery were used in a patient with a tumour located in the frontal horn of the left lateral ventricle. The endoport channel was made of a polyvinyl sheet that was cut into a 7 cm square, rolled into a tubular structure that was wrapped around the neuronavigational probe, and inserted in the access trajectory to the tumour. The endoport tube was then expanded with a balloon to a diameter of 7 mm and a surgical corridor was thus formed. During the purely endoscopic microsurgical lesionectomy, the tumour was completely removed from the frontal horn. The foramen of Monro was released and the septum pellucidum was perforated for better cerebrospinal fluid circulation. Histopathological examination confirmed the tumour as subependymoma. The recovery of the patient was unremarkable.
Conclusion: The expandable endoport system supplemented with neuronavigation is a safe and efficient option for deep-seated tumour removal. The tubular shape of the retractor enables standard microsurgical techniques through minimally invasive approaches and offers an excellent visualization of the underlying lesion.