A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adequate Number of Swallows for Pharyngeal Pressure Measurement of a Subject using High-resolution Manometry. | LitMetric

 The number of pressure measurements that need to be recorded using high-resolution manometry (HRM) for the accurate evaluation of pharyngeal function is not well established.  The purpose of this study is to clarify the number of swallows required to obtain an accurate pharyngeal manometric profile of a person.  Forty healthy adults performed a dry swallow and bolus swallows using 3-, 5-, or 10 ml of water and underwent measurements using the Starlet HRM system. Each subject underwent 10 swallows for each of the four bolus volume conditions.  The mean of up to seven measurements of maximum pre-swallow upper esophageal sphincter pressure with 10 ml of swallow was close to the mean of up to eight measurements in 95% of the subjects. Similarly, the rate of change of the average for the eighth and ninth measurements and the rate of change for the average of the ninth and tenth measurements were less than 5%. When the other parameters were similarly measured up to the sixth measurement, no major change in the average value was observed even if more measurements were taken.  A minimum of six measurements are required, and seven swallows are sufficient for evaluating the pharyngeal manometric profile of a single person. This number of measurements can be a useful criterion when performing HRM measurements on individual subjects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7851372PMC
http://dx.doi.org/10.1055/s-0040-1702966DOI Listing

Publication Analysis

Top Keywords

change average
12
measurements
10
number swallows
8
high-resolution manometry
8
pharyngeal manometric
8
manometric profile
8
rate change
8
swallows
5
adequate number
4
pharyngeal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!