Induction of labour using a balloon catheter is common practice throughout the world, often used in high-risk pregnancies due to the improved safety profile for the fetus compared with pharmacological methods. This report outlines the case of a 2500 mL antepartum haemorrhage on placement of a Foley catheter through the cervix at a secondary obstetric unit in New Zealand. An emergency caesarean section was carried out 20 min after the bleeding onset. No obvious cause for the bleeding was identified at caesarean. The mother required a blood transfusion, but otherwise, did well clinically; the infant required resuscitation at birth and went on to suffer a left middle cerebral artery stroke. At 6 months, he is assumed to have recovered with no long-term sequelae. A literature review has highlighted this was an unprecedented event. We hope to raise awareness of this rare catastrophic adverse outcome given the prevalence of balloon catheter induction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7868272 | PMC |
http://dx.doi.org/10.1136/bcr-2020-239591 | DOI Listing |
JACC Cardiovasc Interv
January 2025
Institut Cardiovasculaire Paris-Sud, Hôpital Privé Jacques Cartier, Ramsay-Santé, Massy, France. Electronic address:
Background: The prevalence of coronary artery disease in patients undergoing transcatheter aortic valve replacement (TAVR) is high. Treatment of a coronary events (CE) after TAVR can be technically challenging.
Objectives: The authors sought to assess the incidence and prognostic impact of CE after TAVR.
J Vasc Surg Cases Innov Tech
April 2025
Department of Cardiovascular Surgery, Higashiosaka City Medical Center, Higashiosaka, Osaka, Japan.
A 69-year-old man with chest pain was diagnosed with acute type B aortic dissection with the entry tear located at distal arch and a distal aortic arch aneurysm. Therefore, we performed debranching thoracic endovascular aortic repair 2 weeks after type B aortic dissection onset. First, the graft was anastomosed to bilateral axillary arteries.
View Article and Find Full Text PDFInt Angiol
December 2024
Department of Radiology, Faculty of Medicine, Kastamonu University, Kastamonu, Türkiye.
Background: An effectively functioning arteriovenous fistula (AVF) is vital for end-stage renal disease patients. This study aims to evaluate the effects of Fogarty balloon catheter dilation on creating an effectively functioning AVF.
Methods: This retrospective cohort study was conducted at our clinic between 2020 and 2022.
Int Angiol
December 2024
Department of Vascular Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China -
Background: This study aimed to investigate the clinical outcomes of percutaneous transluminal angioplasty (PTA) in patients undergoing hemodialysis with different types of superior vena cava obstruction (SVCO) lesions.
Methods: This retrospective observational study recruited patients undergoing hemodialysis with SVCO and analyzed the clinical characteristics of SVCO. Patency rates were collected for patients treated with PTA and were assessed using the t-test, U-test, log-rank test and survival analyses such as the Kaplan-Meier method.
Crit Care
January 2025
Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Background: Advanced respiratory monitoring through the measurement of esophageal pressure (Pes) as a surrogate of pleural pressure helps guiding mechanical ventilation in ICU patients. Pes measurement with an esophageal balloon catheter, the current clinical reference standard, needs complex calibrations and a multitude of factors influence its reliability. Solid-state pressure sensors might be able to overcome these limitations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!