A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Release characteristics of enoxaparin sodium-loaded polymethylmethacrylate bone cement. | LitMetric

Background: This study aimed to prepare the polymethylmethacrylate (PMMA) bone cement release system with different concentrations of enoxaparin sodium (ES) and to investigate the release characteristics of ES after loading into the PMMA bone cement.

Methods: In the experimental group, 40 g Palacos®R PMMA bone cement was loaded with various amount of ES 4000, 8000, 12,000, 16,000, 20,000, and 24,000 AXaIU, respectively. The control group was not loaded with ES. Scanning electron microscopy (SEM) was used to observe the surface microstructure of the bone cement in the two groups. In the experiment group, the mold was extracted continuously with pH7.4 Tris-HCL buffer for 10 days. The extract solution was collected every day and the anti-FXa potency was measured. The experiment design and statistical analysis were conducted using a quantitative response parallel line method.

Results: Under the SEM, it was observed that ES was filled in the pores of PMMA bone cement polymer structure and released from the pores after extraction. There was a burst effect of the release. The release amount of ES on the first day was 0.415, 0.858, 1.110, 1.564, 1.952, and 2.513, respectively, from the six groups with various ES loading amount of 4000, 8000, 12,000, 16,000, 20,000, and 24,000 AXaIU, all reaching the peak of release on the first day. The release decreased rapidly on the next day and entered the plateau phase on the fourth day.

Conclusion: The prepared ES-PMMA bone cement has high application potential in orthopedic surgery. ES-PMMA bone cement shows good drug release characteristics. The released enoxaparin sodium has a local anti-coagulant effect within 24 h after application, but it will not be released for a long time, which is complementary to postoperative anti-coagulation therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7860616PMC
http://dx.doi.org/10.1186/s13018-021-02223-wDOI Listing

Publication Analysis

Top Keywords

bone cement
28
pmma bone
16
release characteristics
12
release
8
bone
8
enoxaparin sodium
8
amount 4000
8
4000 8000
8
8000 12000
8
12000 16000
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!