Multilayers consisting of graphene oxide (GO) and α-FeO thin layers were deposited on the ceramic substrates by the spray LbL (layer by layer) coating technique. Graphene oxide was prepared from graphite using the modified Hummers method. Obtained GO flakes reached up to 6 nanometers in thickness and 10 micrometers in lateral size. Iron oxide FeO was obtained by the wet chemical method from FeCl and NHOH solution. Manufactured samples were deposited as 3 LbL (GO and FeO layers deposited sequentially) and 6 LbL structures with GO as a bottom layer. Electrical measurements show the decrease of multilayer resistance after the introduction of the oxidizing NO gas to the ambient air atmosphere. The concentration of NO was changed from 1 ppm to 20 ppm. The samples changed their resistance even at temperatures close to room temperature, however, the sensitivity increased with temperature. FeO is known as an n-type semiconductor, but the rGO/FeO hybrid structure behaved similarly to rGO, which is p-type. Both chemisorbed O and NO act as electron traps decreasing the concentration of electrons and increasing the effective multilayer conductivity. An explanation of the observed variations of multilayer structure resistance also the possibility of heterojunctions formation was taken into account.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867266 | PMC |
http://dx.doi.org/10.3390/s21031011 | DOI Listing |
ACS Sens
January 2025
School of Chemistry and Molecular Engineering, In Situ Devices Research Center, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China.
Monitoring volatile organic compounds (VOCs) is crucial for ensuring safety and health. In this study, we introduce a strategy to engineer a chromatography-inspired single-sensor (CISS) e-nose tailored for VOC monitoring. This approach overcomes the limitations of traditional methodologies and conventional e-noses.
View Article and Find Full Text PDFDalton Trans
January 2025
Fujian Provincial Key Laboratory of Advanced Materials Oriented Chemical Engineering, College of Chemistry & Materials Science, Fujian Normal University, Fuzhou, Fujian 350007, P. R. China.
The development of Pd-based materials with high activity and long-term stability is crucial for their practical applications as an anode catalyst in direct formic acid fuel cells. Herein, we reveal that the catalytic activity of Pd towards formic acid oxidation can be enhanced by incorporation of a series of rare-earth oxides, including ScO, CeO, LaO, and PrO. For example, Pd nanoparticles incorporated with ScO supported on nitrogen-doped reduced graphene oxide (Pd-ScO/N-rGO-, = 1/3, 1/2, 2/3, 1, and 3/2; "" denotes the molar ratio of Pd : Sc) can be obtained using a sodium borohydride reduction method.
View Article and Find Full Text PDFNanoscale
January 2025
Institute of Inorganic Chemistry, Graz University of Technology, 8010 Graz, Austria.
Among the various types of pancreatic cancers, pancreatic ductal adenocarcinoma (PDAC) is the most lethal and aggressive, due to its tendency to metastasize quickly and has a particularly low five-year survival rate. Carbohydrate antigen 19-9 (CA 19-9) is the only biomarker approved by the Food and Drug Administration for PDAC and has been a focal point in diagnostic strategies, but its sensitivity and specificity are not sufficient for early and accurate detection. To address this issue, we introduce a synergistic approach combining CA 19-9 levels with a graphene oxide (GO)-based blood test.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
Temperature and Humidity Metrology, CSIR-National Physical Laboratory, Dr K. S. Krishnan Marg, New Delhi, 110012, India.
In this study, we have proposed an advanced humidity sensor based on a composite of chitosan (CS) and graphene oxide (GO), prepared by the drop casting method. Graphene oxide-chitosan (GO-CS) films with varying volumetric ratios, along with pure GO and CS films, were prepared and extensively characterized using XRD, Raman, FTIR, SEM, XPS, and water contact angle to study their structural and morphological properties. Comparative analysis of humidity sensing parameters of all prepared films revealed that the film with a volumetric ratio of 4 : 1 (GOCS-2) performs best among all of them, which is attributed to the synergistic interaction between GO and CS.
View Article and Find Full Text PDFRSC Adv
January 2025
College of Food Science and Technology, Jiangsu Agri-animal Husbandry Vocational College Taizhou 225300 China
Bacterial infections are a major global health challenge, posing severe risks to human well-being. Although numerous strategies have been developed to combat bacterial pathogens, their practical application is often hindered by operational constraints. Photocatalytic materials have emerged as promising candidates for bacterial disinfection and food preservation due to their efficiency and sustainability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!