COVID-19 may lead to serious respiratory complications which may necessitate ventilatory support. There is concern surrounding potential release of patient-derived bioaerosol during nebuliser drug refill, which could impact the health of caregivers. Consequently, mesh nebulisers have been recommended by various clinical practice guidelines. Currently, there is a lack of empirical data describing the potential for release of patient-derived bioaerosol during drug refill. This study examined the release of simulated patient-derived bioaerosol, and the effect on positive end expiratory pressure during nebuliser refill during mechanical ventilation of a simulated patient. During jet nebuliser refill, the positive end expiratory pressure decreased from 4.5 to 0 cm HO. No loss in pressure was noted during vibrating mesh nebuliser refill. A median particle number concentration of 710 particles cm above ambient was detected when refilling the jet nebuliser in comparison to no increase above ambient detected when using the vibrating mesh nebuliser. The jet nebuliser with the endotracheal tube clamped resulted in 60 particles cm above ambient levels. This study confirms that choice of nebuliser impacts both the potential for patient-derived bioaerosol release and the ability to maintain ventilator circuit pressures and validates the recommended use of mesh nebulisers during mechanical ventilation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7912998 | PMC |
http://dx.doi.org/10.3390/pharmaceutics13020199 | DOI Listing |
Front Med (Lausanne)
December 2022
Research & Development, Science & Emerging Technologies, Aerogen Limited, Galway, Ireland.
The use of high-flow nasal cannula in the treatment of COVID-19 infected patients has proven to be a valuable treatment option to improve oxygenation. Early in the pandemic, there were concerns for the degree of risk of disease transmission to health care workers utilizing these treatments that are considered aerosol generating procedures. This study developed an model to examine the release of simulated patient-derived bioaerosol with and without high-flow nasal cannula at gas flow rates of 30 and 50 L/min.
View Article and Find Full Text PDFDrug Deliv
December 2021
Research and Development, Science and Emerging Technologies, Aerogen, Galway, Ireland.
COVID-19 can cause serious respiratory complications resulting in the need for invasive ventilatory support and concurrent aerosol therapy. Aerosol therapy is considered a high risk procedure for the transmission of patient derived infectious aerosol droplets. Critical-care workers are considered to be at a high risk of inhaling such infectious droplets.
View Article and Find Full Text PDFPharmaceutics
February 2021
Aerogen Limited, Galway Business Park, H91 HE94 Galway, Ireland.
COVID-19 may lead to serious respiratory complications which may necessitate ventilatory support. There is concern surrounding potential release of patient-derived bioaerosol during nebuliser drug refill, which could impact the health of caregivers. Consequently, mesh nebulisers have been recommended by various clinical practice guidelines.
View Article and Find Full Text PDFPLoS One
October 2020
Institute of Infectious Disease and Molecular Medicine, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.
Introduction: Detection of Mycobacterium tuberculosis (Mtb) in patient-derived bioaerosol is a potential tool to measure source case infectiousness. However, current bioaerosol sampling approaches have reported low detection yields in sputum-positive TB cases. To increase the utility of bioaerosol sampling, we present advances in bioaerosol collection and Mtb identification that improve detection yields.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!