In this study, three up-flow fixed-bed bioreactors, named as A, B, and C, packed with polycaprolactone (PCL) under different filling ratios (31%, 62%, and 93%, respectively), were investigated over a long period (96 days). During the stable period, the mean effluent concentrations in reactors A, B, and C were 1.35 ± 0.50, 1.07 ± 0.41, and 1.03 ± 0.27 mg/L, respectively, which showed the removal of was not closely related to filling ratio (p > 0.05, one-way ANOVA). However, it was found that biomass in reactor A was 2.13 and 5.55 times in B and C, respectively. Excessively thick biofilm refrained the enzymatic hydrolysis of PCL and biofilm's specific denitrification rate (SDNR). Backwash stimulated organic matter release and enabled biofilm to restore its denitrification activity. The maximum cycle of backwash was 6 days for the lowest filling ratio reactor. Additionally, the utilization rates for denitrification were 83.3%, 86.4%, and 60.5% in reactors A, B, and C, respectively, which was higher after backwash than before backwash. PRACTITIONER POINTS: Excessively thick biofilm refrained the enzymatic hydrolysis of PCL. Backwash stimulated organic matter release and enabled biofilm to restore its denitrification activity. The maximum cycle of backwash was 6 days for the lowest filling ratio reactor. A higher utilization rate of PCL for denitrification was observed after backwash.