Blunt traumatic aortic tear is an extremely rare and life-threatening paediatric emergency. Percutaneous repair is highly debateable in children due to anatomic limitations. Herein, we report an important case of a 5-year-old boy diagnosed with grade 3 aortic isthmus disruption following fifth-floor defenestration. The 96-h control computerized tomography (CT) scan showed an increase in the pseudoaneurysm size with small active bleeding motivating endovascular covered stenting that was safely and efficiently performed with good outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezab029DOI Listing

Publication Analysis

Top Keywords

aortic isthmus
8
endovascular stenting
4
stenting blunt
4
blunt aortic
4
isthmus rupture
4
rupture 5-year-old
4
5-year-old child
4
child blunt
4
blunt traumatic
4
traumatic aortic
4

Similar Publications

Third trimester fetal 4D flow MRI with motion correction.

Magn Reson Med

January 2025

Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.

Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.

Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.

View Article and Find Full Text PDF

Advances in the Treatment of Neonatal Coarctation of the Aorta.

Pediatrics

January 2025

Department of Pediatric Cardiology and Critical Care, Hannover Medical School, Hannover, Germany.

Coarctation of the aorta (CoA) is a potentially life-threatening congenital and obstructive anomaly of the distal aortic arch. After constriction of the ductus arteriosus, neonates may develop critical CoA in the isthmus area and present with severe left ventricular dysfunction or even cardiac failure. Low cardiac output and abdominal hypoperfusion (distal to the coarctation) may lead to metabolic derangements and clinical deterioration.

View Article and Find Full Text PDF

A novel diagnostic model for fetal coarctation of the aorta with ventricular septal defect.

Int J Cardiol

December 2024

Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China; Clinical Research Center for Medical Imaging in Hubei Province, Wuhan, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China. Electronic address:

Background: Our study aimed to develop a novel diagnostic model for fetal coarctation of the aorta with ventricular septal defect(CoA/VSD).

Methods And Results: We respectively included 70 fetuses with suspected CoA/VSD(January 2017-June 2023). After birth, 26 fetuses (26/47, 55.

View Article and Find Full Text PDF

A 77-year-old man had severe aortic stenosis and continuous atrial fibrillation. We performed maze procedure without left atrial incision( Dallas lesion set) during aortic valve replacement for this patient. Dallas lesion set alternates the isolation of mitral isthmus by connecting ablation line beneath left coronary cusp and noncoronary cusp commissure of the aortic valve with ablation from epicardial side of the upper left atrium.

View Article and Find Full Text PDF

Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester.

Radiol Cardiothorac Imaging

December 2024

From the Departments of Radiology (E.K.E., T.F., M.L.M., L.P.B., A.J.B.), Pediatrics-Cardiology (R.M.F.), and Bioengineering (A.J.B.), University of Colorado Anschutz Medical Campus, 13123 E 16th Ave B125, Aurora, CO 80045; and Department of Radiology, Children's Hospital Colorado, Aurora, Colo (S.A.S., A.J.B.).

Article Synopsis
  • The study aimed to establish reference values for fetal 4D flow MRI and assess its reliability in measuring blood flow in healthy fetuses and those with suspected aortic coarctation (CoA).
  • Researchers conducted MRI scans on 34 pregnant patients, collecting data from both healthy fetuses and those with potential cardiovascular issues, analyzing the accuracy and consistency of the flow measurements obtained.
  • The results indicated that fetal 4D flow MRI provides reliable hemodynamic measurements with high precision and repeatability, although it tends to underestimate blood flow compared to traditional 2D phase contrast MRI techniques.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!