AI Article Synopsis

  • The study evaluated the implementation of an independent clinical event committee (CEC) process in the GLOBAL LEADERS trial, focusing on how effectively events like myocardial infarction and bleeding were adjudicated and compared to investigator-reported events.
  • Results showed high adjudication rates for both investigator-reported (IR) and non-IR triggers, with global diagnostic accuracy ranging from 0.54 to 0.77, indicating variable levels of agreement between IR and CEC assessments.
  • Conclusions suggest that while CEC adjudication can enhance outcome assessment in open-label trials, the consistency of IR event reports, especially for bleeding and stent thrombosis, remains a concern.

Article Abstract

Background: Event adjudication by a clinical event committee (CEC) provides a standardized, independent outcome assessment. However, the added value of CEC to investigators reporting remains debated. GLASSY (GLOBAL LEADERS Adjudication Sub-Study) implemented, in a subset of the open-label, investigator-reported (IR) GLOBAL LEADERS trial, an independent adjudication process of reported and unreported potential outcome events (triggers). We describe metrics of GLASSY feasibility and efficiency, diagnostic accuracy of IR events, and their concordance with corresponding CEC-adjudicated events.

Methods: We report the proportion of myocardial infarction, bleeding, stroke, and stent thrombosis triggers with sufficient evidence for assessment (feasibility) that were adjudicated as outcome events (efficiency), stratified by source (IR or non-IR). Using CEC-adjudicated events as criterion standard, we describe sensitivity, specificity, positive and negative predictive value, and global diagnostic accuracy of IR events. Using Gwet AC coefficient, we examine the concordance between IR- and corresponding CEC-adjudicated triggers. There was sufficient evidence for assessment for 2592 (98.3%) of 2636 triggers.

Results: Overall, the adjudicated end point-to-trigger ratio was high and similar between IR- (88%) and non-IR-reported (87%) triggers. The global diagnostic accuracy and concordance between IR-reported and CEC-adjudicated outcome events was 0.70 (95% CI, 0.65-0.74) and 0.54 (95% CI, 0.45-0.62), respectively, for myocardial infarction; 0.77 (95% CI, 0.75-0.79) and 0.71 (95% CI, 0.68-0.74) for bleeding; 0.70 (95% CI, 0.62-0.79) and 0.59 (95% CI, 0.43-0.74) for stroke; 0.59 (95% CI, 0.52-0.66) and 0.39 (95% CI, 0.25-0.53) for stent thrombosis. For IR bleedings, the concordance with the CEC on type of events was generally weak.

Conclusions: Implementing CEC adjudication in a pragmatic open-label trial with IR events is feasible and efficient. Our findings of modest global diagnostic accuracy for IR events and generally weak concordance between investigators and CEC support the role for CEC adjudication in such settings. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03231059.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCOUTCOMES.120.006581DOI Listing

Publication Analysis

Top Keywords

outcome events
16
diagnostic accuracy
16
accuracy events
12
global diagnostic
12
events
10
clinical event
8
global leaders
8
corresponding cec-adjudicated
8
myocardial infarction
8
stent thrombosis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!