A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of Indoor Thoron Gas Concentrations Using a Radon-Thoron Discriminative Passive Type Monitor: Nationwide Survey in Japan. | LitMetric

Measurement of Indoor Thoron Gas Concentrations Using a Radon-Thoron Discriminative Passive Type Monitor: Nationwide Survey in Japan.

Int J Environ Res Public Health

Department of Radiological Technology, Faculty of Health Sciences, Hokkaido University of Science, Sapporo, Hokkaido 006-8585, Japan.

Published: February 2021

As part of a nationwide survey of thoron (Rn) in Japan, the indoor Rn gas concentrations in 940 dwellings were measured throughout one year, from 1993 to 1996, using a passive type Rn-Rn discriminative monitor. The monitor was placed in a bedroom or a living room in each house for four successive three-month periods. The mean annual indoor Rn concentration was estimated from the four measurements in each house. The arithmetic mean, the median and the geometric mean for indoor Rn concentrations in 899 dwellings were 20.1, 9.6 and 10.0 Bq m, respectively. The Rn concentrations exhibited a log-normal distribution. It was found that the Rn concentrations were dependent on the nature of the materials used for wall construction and also on the distance of measurement from the wall. Significant seasonal variations in the Rn concentration were not observed. It would seem that the nature of the wall material contributed to the increased indoor Rn concentrations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7908141PMC
http://dx.doi.org/10.3390/ijerph18031299DOI Listing

Publication Analysis

Top Keywords

gas concentrations
8
passive type
8
nationwide survey
8
indoor concentrations
8
concentrations
6
measurement indoor
4
indoor thoron
4
thoron gas
4
concentrations radon-thoron
4
radon-thoron discriminative
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!