Machine Embroidered Sensors for Limb Joint Movement-Monitoring Smart Clothing.

Sensors (Basel)

Department of Clothing &Textiles, Yonsei University, Seoul 03722, Korea.

Published: February 2021

In this study, a strain gauge sensor based on a change of contact or network structure between conductive materials was implemented using the handle-machine embroidery technique, and the variables (embroidery shape, embroidery distance, embroidery size, and implementation location) affecting its performance were studied. As a result of Experiment I on the structure of embroidery suitable for joint motion monitoring, the embroidery distance, rather than the embroidery size, was found to have a significant effect on the electric resistance changes caused by elongation. Based on the results of Experiment I, two types of zigzag embroideries, four types of embroideries with few contact points, and two types of embroideries with more contact points (all with short distances (2.0)) were selected for Experiment II (the dummy motion experiment). As a result of the dummy motion experiment, it was found that the locations of the suitable embroidered sensors for joint motion monitoring was the HJP (Hinge Joint Position) in the 'types without a contact point' (zigzag) and the LHJP (Lower Hinge Joint Position) in the 'types with more contact points'. On the other hand, although there was no consistency among the 'types with few contact points', the resistance changes measured by the 2CP and 7CP embroidered sensors showed similar figures and patterns, and the HJP location was most suitable. The resistance changes measured by the 4CP and 6CP embroidered sensors exhibited no consistent patterns, but the LHJP locations were more suitable. These results indicate that the location of the HJP is suitable for measuring joint motion in the 'type without a contact point', and the location of the LHJP is suitable for measuring joint motion when the number of contact points exceeds a certain limit. Among them, the average resistance change of the 9CP sensor located at the LHJP was 40 Ω with the smallest standard deviation of less than 1, and it is thus considered to have the best performance among all the sensors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867096PMC
http://dx.doi.org/10.3390/s21030949DOI Listing

Publication Analysis

Top Keywords

embroidered sensors
16
joint motion
16
resistance changes
12
contact points
12
'types contact
12
contact
8
embroidery distance
8
distance embroidery
8
embroidery size
8
motion monitoring
8

Similar Publications

This paper presents an enhanced measurement technique for evaluating embroidered transmission lines (TLs), based on a TL characterization method. The evaluation metric is the "pure" losses of the embroidered TL excluding mismatch losses. Enhanced mechanical stability and removability of embroidered samples under a test is supported by a specially designed measurement setup.

View Article and Find Full Text PDF

Embroidered Interdigitated Electrodes (IDTs) with Wireless Readout for Continuous Biomarker Monitoring.

Sensors (Basel)

July 2024

Smart Materials & Surfaces Laboratory-E-Textiles Centre, Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK.

Non-invasive continuous health monitoring has become feasible with the advancement of biosensors. While monitoring certain biomarkers such as heart rate or skin temperature are now at a certain maturity, monitoring molecular biomarkers is still challenging. Progress has been shown in sampling, measurement, and interpretation of data toward non-invasive molecular sensors that can be integrated into daily wearable items.

View Article and Find Full Text PDF

Embroidery Triboelectric Nanogenerator for Energy Harvesting.

Sensors (Basel)

June 2024

Centre for Textile Science and Engineering, Department of Materials, Textiles and Chemical Engineering (MATCH), Ghent University, Technologie park 70A, 9052 Ghent, Belgium.

Triboelectric nanogenerators (TENGs) are devices that efficiently transform mechanical energy into electrical energy by utilizing the triboelectric effect and electrostatic induction. Embroidery triboelectric nanogenerators (ETENGs) offer a distinct prospect to incorporate energy harvesting capabilities into textile-based products. This research work introduces an embroidered triboelectric nanogenerator that is made using polyester and nylon 66 yarn.

View Article and Find Full Text PDF

Textronic Capacitive Sensor with an RFID Interface.

Sensors (Basel)

June 2024

Department of Electronic and Telecommunications Systems, Rzeszów University of Technology, ul. Wincentego Pola 2, 35-959 Rzeszów, Poland.

This article presents an innovative combination of textile electrical circuits with advanced capabilities of electronic RFID sensors, indicating the revolutionary nature of the development of textronics, which is used in various areas of life, from fashion to medicine. A review of the literature relating to the construction of textronic RFID identifiers and capacitive textronic sensors is performed. Various approaches to measuring capacity using RFID tags are discussed.

View Article and Find Full Text PDF

Microfluidic Sensing Textile for Continuous Monitoring of Sweat Glucose at Rest.

ACS Appl Mater Interfaces

April 2024

Key Laboratory for Ultrafine Materials of Ministry of Education, Frontiers Science Center for Materiobiology and Dynamic Chemistry, School of Materials Science and Engineering, East China University of Science & Technology, Shanghai 200237, China.

Wearable sweat sensors have received considerable attention due to their great potential for noninvasive continuous monitoring of an individual's health status applications. However, the low secretion rate and fast evaporation of sweat pose challenges in collecting sweat from sedentary individuals for noninvasive analysis of body physiology. Here, we demonstrate wearable textiles for continuous monitoring of sweat at rest using the combination of a heating element and a microfluidic channel to increase localized skin sweat secretion rates and combat sweat evaporation, enabling accurate and stable monitoring of trace amounts of sweat.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!