Objective: The aim of this study was to investigate the performance of screening for open spina bifida (OSB) integrated into the routine first-trimester screening.

Method: This is a prospective multicentre study of 4,755 women undergoing first-trimester ultrasound scans over a 4-year period. Measurements of the brainstem (BS) diameter and brainstem-to-occipital-bone (BSOB) distance were performed. The cisterna magna (CM) was measured in the tilted axial view.

Results: Pregnancy outcome data were available for 4,658 fetuses included in this study. There were 5 fetuses with OSB, and in all of them, the BS/BSOB ratio and the CM measurements were abnormal. The sensitivity and specificity of a BS/BSOB ratio >1 were 100%. The sensitivity of a CM width <5th centile was 100%, and the specificity was 95.1%. In 4.6% of cases, the BS/BSOB ratio was between the 95th percentile and 1. In 87.1% of these cases, the CM was normal, and 12.9% had a CM below the 5th percentile.

Conclusion: Screening for OSB is feasible in routine first-trimester scans. The BS/BSOB ratio shows a very good sensitivity and specificity. In cases with near-normal values for the BS/BSOB ratio, the CM width might be helpful for further assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000512487DOI Listing

Publication Analysis

Top Keywords

screening open
8
open spina
8
spina bifida
8
prospective multicentre
8
bs/bsob ratio
8
bifida routine
4
routine clinical
4
clinical setting
4
setting first-trimester
4
first-trimester scan
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!