Effect of non-Newtonian fluid rheology on an arterial bypass graft: A numerical investigation guided by constructal design.

Comput Methods Programs Biomed

Department of Industrial Engineering (DIN), School of Engineering and Architecture, Alma Mater Studiorum - University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy. Electronic address:

Published: April 2021

In post-operative scenarios of arterial graft surgeries to bypass coronary artery stenosis, fluid dynamics plays a crucial role. Problems such as intimal hyperplasia have been related to fluid dynamics and wall shear stresses near the graft junction. This study focused on the question of the use of Newtonian and non-Newtonian models to represent blood in this type of problem in order to capture important flow features, as well as an analysis of the performance of geometry from the view of Constructive Theory. The objective of this study was to investigate the effects rheology on the steady-state flow and on the performance of a system consisting of an idealized version of a partially obstructed coronary artery and bypass graft. The Constructal Design Method was employed with two degrees of freedom: the ratio between bypass and artery diameters and the junction angle at the bypass inlet. The flow problem was solved numerically using the Finite Volume Method with blood modeled employing the Carreau equation for viscosity. The Computational Fluid Dynamics model associated with the Sparse Grid method generated eighteen response surfaces, each representing a severe stenosis degree of 75% for specific combinations of rheological parameters, dimensionless viscosity ratio, Carreau number and flow index at two distinct Reynolds numbers of 150 and 250. There was a considerable dependence of the pressure drop on rheological parameters. For the two Reynolds numbers studied, the Newtonian case presented the lowest value of the dimensionless pressure drop, suggesting that the choice of applying Newtonian blood may underestimate the value of pressure drop in the system by about 12.4% (Re =150) and 7.8% (Re = 250). Even so, results demonstrated that non-Newtonian rheological parameters did not influence either the shape of the response surfaces or the optimum bypass geometry, which consisted of a diameter ratio of 1 and junction angle of 30°. However, the viscosity ratio and the flow index had the greatest impact on pressure drop, recirculation zones and wall shear stress. Rheological parameters also affected the recirculation zones downstream of stenosis, where intimal hyperplasia is more prevalent. Newtonian and most non-Newtonian results had similar wall shear stresses, except for the non-Newtonian case with high viscosity ratio. In the view of Constructal Design, the geometry of best performance was independent of the rheological model. However, rheology played an important role on pressure drop and flow dynamics, allowing the prediction of recirculation zones that were not captured by a Newtonian model.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2021.105944DOI Listing

Publication Analysis

Top Keywords

pressure drop
20
rheological parameters
16
constructal design
12
fluid dynamics
12
wall shear
12
viscosity ratio
12
recirculation zones
12
bypass graft
8
coronary artery
8
intimal hyperplasia
8

Similar Publications

: The PreserFlo™ MicroShunt (PFMS) is a bleb-forming device considered to be less invasive than traditional glaucoma surgery such as trabeculectomy. This study evaluates the 1-year success rates as well as safety profile of PFMS in patients having high intraocular pressure (IOP) and/or glaucoma refractory to drop therapy with a history of prior intravitreal dexamethasone therapy. : A total of 16 eyes after PFMS implantation due to elevated IOP after intravitreal dexamethasone implant (DEX-I) administration were included in this retrospective cohort study.

View Article and Find Full Text PDF

Myalgic Encephalomyelitis or Chronic Fatigue Syndrome (ME/CFS) is a chronic multisystem disease characterized by severe muscle fatigue, pain, dizziness, and brain fog. The two most common symptoms are post-exertional malaise (PEM) and orthostatic intolerance (OI). ME/CFS patients with OI (ME+OI) suffer from dizziness or faintness due to a sudden drop in blood pressure while maintaining an upright posture.

View Article and Find Full Text PDF

An interface can be delicately designed using interactions between nanoparticles and surfactants by controlling surface properties such as activity and charge equilibrium. This study seeks to provide insights into how surfactant concentration impacts the stability and dynamics of nanoparticle-surfactant interfaces, with potential applications in material science and interface engineering. This study investigates the interactions between Graphene Function (Gr, Graphene function in this text refers to functionalizing the graphene sheets with -COOH groups via acidic reactions.

View Article and Find Full Text PDF

Background: Hypertension has shown a trend of prevalence at younger ages, and the non-dipping pattern is associated with target organ damage in hypertension. However, few studies have yet investigated the clinical characteristics and risk factors of non-dipper status in essential hypertension children. This study aimed to explore the clinical characteristics and possible indicators associated with non-dipper status in children with essential hypertension.

View Article and Find Full Text PDF

As a necessary part of intelligent control of a joint station, the automatic identification of abnormal conditions and automatic adjustment of operation schemes need to judge the running state of the system. In this paper, a combination of Particle Swarm Optimization (PSO) and Gray Wolf Optimizer (GWO) is proposed to optimize the Backpropagation Neural Network (BP) model (PSO-GWO-BP) and a pressure drop prediction model for the joint station export system is established using PSO-GWO-BP. Compared with the traditional hydraulic calculation modified (THCM) models and other machine learning algorithms, the PSO-GWO-BP model has significant advantages in prediction accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!