A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Removal and Inactivation of an Enveloped Virus Surrogate by Iron Conventional Coagulation and Electrocoagulation. | LitMetric

Removal and Inactivation of an Enveloped Virus Surrogate by Iron Conventional Coagulation and Electrocoagulation.

Environ Sci Technol

Department of Civil & Environmental Engineering, Texas A&M University, College Station, Texas 77843-3136, United States.

Published: February 2021

It is imperative to understand the behavior of enveloped viruses during water treatment to better protect public health, especially in the light of evidence of detection of coronaviruses in wastewater. We report bench-scale experiments evaluating the extent and mechanisms of removal and/or inactivation of a coronavirus surrogate (ϕ6 bacteriophage) in water by conventional FeCl coagulation and Fe(0) electrocoagulation. Both coagulation methods achieved ∼5-log removal/inactivation of ϕ6 in 20 min. Enhanced removal was attributed to the high hydrophobicity of ϕ6 imparted by its characteristic phospholipid envelope. ϕ6 adhesion to freshly precipitated iron (hydr)oxide also led to envelope damage causing inactivation in both coagulation techniques. Fourier transform infrared spectroscopy revealed oxidative damages to ϕ6 lipids only for electrocoagulation consistent with electro-Fenton reactions. Monitoring ϕ6 dsRNA by a novel reverse transcription quantitative polymerase chain reaction (RT-qPCR) method quantified significantly lower viral removal/inactivation in water compared with the plaque assay demonstrating that relying solely on RT-qPCR assays may overstate human health risks arising from viruses. Transmission electron microscopy and computationally generated electron density maps of ϕ6 showed severe morphological damages to virus' envelope and loss of capsid volume accompanying coagulation. Both conventional and electro- coagulation appear to be highly effective in controlling enveloped viruses during surface water treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.est.0c07697DOI Listing

Publication Analysis

Top Keywords

enveloped viruses
8
water treatment
8
ϕ6
7
coagulation
6
removal inactivation
4
inactivation enveloped
4
enveloped virus
4
virus surrogate
4
surrogate iron
4
iron conventional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!