Biomimetic phantom with anatomical accuracy for evaluating brain volumetric measurements with magnetic resonance imaging.

J Med Imaging (Bellingham)

University of São Paulo, Department of Computing and Mathematics, Faculty of Philosophy, Science and Languages, Ribeirão Preto, São Paulo, Brazil.

Published: January 2021

Brain image volumetric measurements (BVM) methods have been used to quantify brain tissue volumes using magnetic resonance imaging (MRI) when investigating abnormalities. Although BVM methods are widely used, they need to be evaluated to quantify their reliability. Currently, the gold-standard reference to evaluate a BVM is usually manual labeling measurement. Manual volume labeling is a time-consuming and expensive task, but the confidence level ascribed to this method is not absolute. We describe and evaluate a biomimetic brain phantom as an alternative for the manual validation of BVM. We printed a three-dimensional (3D) brain mold using an MRI of a three-year-old boy diagnosed with Sturge-Weber syndrome. Then we prepared three different mixtures of styrene-ethylene/butylene-styrene gel and paraffin to mimic white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF). The mold was filled by these three mixtures with known volumes. We scanned the brain phantom using two MRI scanners, 1.5 and 3.0 Tesla. Our suggestion is a new challenging model to evaluate the BVM which includes the measured volumes of the phantom compartments and its MRI. We investigated the performance of an automatic BVM, i.e., the expectation-maximization (EM) method, to estimate its accuracy in BVM. The automatic BVM results using the EM method showed a relative error (regarding the phantom volume) of 0.08, 0.03, and 0.13 ( uncertainty) percentages of the GM, CSF, and WM volume, respectively, which was in good agreement with the results reported using manual segmentation. The phantom can be a potential quantifier for a wide range of segmentation methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7844423PMC
http://dx.doi.org/10.1117/1.JMI.8.1.013503DOI Listing

Publication Analysis

Top Keywords

volumetric measurements
8
magnetic resonance
8
resonance imaging
8
bvm
8
bvm methods
8
evaluate bvm
8
brain phantom
8
three mixtures
8
automatic bvm
8
brain
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!