Introduction: By providing timely actionable results for prompt management, point-of-care testing (POCT) kits have revolutionised medical care for various diseases, ranging from infectious diseases like malaria to genetic disorders, such as sickle cell disease (SCD). They are, however, underutilised in the diagnosis of SCD in developing countries, where the need is greatest.

Objective: The study was aimed at assessing the sensitivity of HemoTypeSC POCT among a cohort of children with SCD, previously diagnosed by Alkaline cellulose acetate hemoglobin electrophoresis (ACAE), with or without high-performance liquid chromatography (HPLC).

Methods: In this descriptive cross-sectional study, HemoTypeSC test was conducted on all participants and its sensitivity was determined by comparing results with those obtained using ACAE. Discordance was verified with HPLC.

Results: One hundred and forty-five children aged one to 19 years were studied. There were 84 males and 61 females (male: female ratio = 1.4: 1). The HemoTypeSC was able to correctly diagnose sickle cell anemia (SCA) and hemoglobin SC in all (100%) of the children tested.

Conclusion: The HemoTypeSC shows high sensitivity in detecting SCA and hemoglobin SC. Hence, it is useful for targeted screening of individuals suspected of having SCD, leading to rapid diagnosis of these hemoglobinopathies, even in resource-constrained settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477771PMC
http://dx.doi.org/10.1016/j.htct.2020.11.010DOI Listing

Publication Analysis

Top Keywords

point-of-care testing
8
high sensitivity
8
alkaline cellulose
8
cellulose acetate
8
acetate hemoglobin
8
hemoglobin electrophoresis
8
sickle cell
8
sca hemoglobin
8
hemotypesc
5
hemoglobin
5

Similar Publications

Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).

View Article and Find Full Text PDF

Background: Real-time and rapid detection of ingredients in food has important significance for food safety. However, traditional detection methods not only require bulky and costly instruments but also are often based on single-mode analysis, limiting their accuracy and applications in point-of-care testing. Herein, an integrated and miniaturized dual-mode device based on colorimetric and photoacoustic (PA) principles is developed, using Au@Ag nanoparticles (Au@AgNPs) as signal probe and ascorbic acid (AA) and ascorbate oxidase (AAO) as analytes.

View Article and Find Full Text PDF

Fast is fine, but accuracy is everything: making intraoperative transfusion decisions using point-of-care testing.

Br J Anaesth

February 2025

Transfusion Research Unit, Department of Public Health and Preventative Medicine, Monash University, Melbourne, VIC, Australia; Department of Clinical Haematology, Monash Health, Clayton, VIC, Australia.

Accurate and timely diagnostic information is a vital adjunct to clinical assessment to inform therapeutic decision-making, including decisions to transfuse, or not transfuse, blood components. A prospective cohort study of diagnostic point-of-care (POC) haemoglobin measurements on arterial or central venous samples from adults undergoing major noncardiac surgery compared three widely used devices, HemoCue®, i-STAT™, and the Rad-67™ pulse CO-Oxymeter® finger sensor device, against standard laboratory haemoglobin measurements, but importantly not against a blood gas analyser. The study focused on haemoglobin results below 100 g L to establish the utility of these devices to guide red cell transfusion decisions.

View Article and Find Full Text PDF

A machine-learning-integrated portable electrochemiluminescence sensing platform for the visualization and high-throughput immunoassays.

Talanta

January 2025

College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong 518060, PR China. Electronic address:

Electrochemiluminescence (ECL)-based point-of-care testing (POCT) has the potential to facilitate the rapid identification of diseases, offering advantages such as high sensitivity, strong selectivity, and minimal background interference. However, as the throughput of these devices increases, the issues of increased energy consumption and cross-contamination of samples remain. In this study, a high-throughput ECL biosensor platform with the assistance of machine learning algorithms is developed by combining a microcolumn array electrode, a microelectrochemical workstation, and a smartphone with custom software.

View Article and Find Full Text PDF

Objective: To measure the prevalence of antibiotic use in dogs and cats, identify the most common antibiotic drugs prescribed, and determine the most common indications for use.

Methods: Point-prevalence survey methodology was used to collect antibiotic prescribing data for cats and dogs from 1 practice day in 2021 at nonacademic primary care and referral practices in the US.

Results: 52 practices participated, comprising records for 2,599 dogs and cats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!