This study aimed to determine applicable value of DWIBS in diagnosis of solitary pulmonary lesions. This study involved 32 solitary lung disease patients. T1W1, T2W1, T2WI-SPAIR were examined using MRI scanner and analyzed with View-forum 6.0 workstation. Imaging characteristics of pulmonary solitary lesions on DWIBS and ADC when b=300, 500 and 800 s/mm were observed. Signal-to-noise ratio (SNR), contrast-noise-ratio (CNR) and ADC value of lesions under different b-values were measured. Image quality in different b-values was compared by analyzing SNR and CNR. ADC values of benign and malignant lesions in different b-value groups were tested using -test. ROC curve was used to evaluate diagnostic efficacy of ADC value, and obtain diagnostic threshold. The results indicated that SNR and CNR value of 300 and 500 s/mm group was significantly higher compared to 800 s/mm group (<0.05). When b-value was assigned as 500 s/mm, DWIBS demonstrated better and ideal images. ADC value of malignant lesions in different b-values was significantly lower compared to benign lesions (<0.05), suggesting ADC value is a feasible approach for distinguishing benign from malignant lesions. AUC value of b=500 s/mm was significantly higher compared to b=300 and b=800 s/mm group (<0.05). When b-value was assigned as 500 s/mm, the best ADC threshold value was 1.435×10 mm/s, with high sensitivity, specificity and accuracy of 80.0%, 83.3% and 84.4%, respectively. In conclusion, quantitative analysis of DWIBS examination and ADC value was helpful for qualitative diagnosis of pulmonary solitary lesions, and demonstrated potential to distinguish benign and malignant pulmonary solitary lesions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7847530PMC

Publication Analysis

Top Keywords

pulmonary solitary
8
solitary lesions
8
lesions study
8
800 s/mm
8
cnr adc
8
snr cnr
8
s/mm group
8
lesions
6
diffusion-weighted imaging
4
imaging background
4

Similar Publications

Interobserver Variability in Manual Versus Semi-Automatic CT Assessments of Small Lung Nodule Diameter and Volume.

Tomography

December 2024

Centre for Research and Development, Uppsala University, Region Gävleborg, SE 801 88 Gävle, Sweden.

Background: This study aimed to assess the interobserver variability of semi-automatic diameter and volumetric measurements versus manual diameter measurements for small lung nodules identified on computed tomography scans.

Methods: The radiological patient database was searched for CT thorax examinations with at least one noncalcified solid nodule (∼3-10 mm). Three radiologists with four to six years of experience evaluated each nodule in accordance with the Fleischner Society guidelines using standard diameter measurements, semi-automatic lesion diameter measurements, and volumetric assessments.

View Article and Find Full Text PDF

Objective: Image-guided diagnosis and treatment of lung lesions is an active area of research. With the growing number of solutions proposed, there is also a growing need to establish a standard for the evaluation of these solutions. Thus, realistic phantom and preclinical environments must be established.

View Article and Find Full Text PDF

One-Step Nucleic Acid Amplification Analysis of Sentinel Nodes in Endometrial Cancer Versus Ultrastaging: First Long-Term Follow-Up Data of Discordant Cases.

Cancer Rep (Hoboken)

December 2024

Department of Gynaecology and Obstetrics, University Hospital Pilsen and Faculty of Medicine in Pilsen, Charles University, Plzeň-Lochotín, Czech Republic.

Aims: Endometrial cancer (EC) is the most common gynecological cancer worldwide and its incidence is rising. The cornerstone of its management is surgical treatment with nodal staging. A monocentric study investigating the potential of the molecular biology method of one-step nucleic acid amplification (OSNA) in sentinel lymph node (SLN) analysis was conducted at our institution between April 2016 and January 2018.

View Article and Find Full Text PDF

Background: The detection and classification of lung nodules are crucial in medical imaging, as they significantly impact patient outcomes related to lung cancer diagnosis and treatment. However, existing models often suffer from mode collapse and poor generalizability, as they fail to capture the complete diversity of the data distribution. This study addresses these challenges by proposing a novel generative adversarial network (GAN) architecture tailored for semi-supervised lung nodule classification.

View Article and Find Full Text PDF

Comparison of different localization needles and postures in localization of pulmonary nodules.

J Cardiothorac Surg

December 2024

Department of Thoracic Surgery, The First Hospital of China Medical University, No. 155, Nanjing North Street, Shenyang, 110002, Liaoning, P.R. China.

Background: With advancements in imaging testing and surgical procedures, an increasing number of nodules with smaller diameters and deeper locations have been deemed suitable for surgical intervention. The preoperative localization of these nodules has become essential. In this retrospective single-center study, we aimed to compare the effectiveness and patient comfort associated with the use of a four-hook needle versus a hook-wire needle for preoperative localization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!