Lactate is widely measured in critically ill patients as a robust indicator of patient deterioration and response to treatment. Plasma concentrations represent a balance between lactate production and clearance. Analysis has typically been performed with the aim of detecting tissue hypoxia. However, there is a diverse range of processes unrelated to increased anaerobic metabolism that result in the accumulation of lactate, complicating clinical interpretation. Further, lactate levels can change rapidly over short spaces of time, and even subtle changes can reflect a profound change in the patient's condition. Hence, there is a significant need for frequent lactate monitoring in critical care. Lactate monitoring is commonplace in sports performance monitoring, given the elevation of lactate during anaerobic exercise. The desire to continuously monitor lactate in athletes has led to the development of various technological approaches for non-invasive, continuous lactate measurements. This review aims firstly to reflect on the potential benefits of non-invasive continuous monitoring technology within the critical care setting. Secondly, we review the current devices used to measure lactate non-invasively outside of this setting and consider the challenges that must be overcome to allow for the translation of this technology into intensive care medicine. This review will be of interest to those developing continuous monitoring sensors, opening up a new field of research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7865822PMC
http://dx.doi.org/10.3390/s21030879DOI Listing

Publication Analysis

Top Keywords

non-invasive continuous
12
lactate monitoring
12
critical care
12
lactate
11
continuous lactate
8
monitoring critical
8
care lactate
8
continuous monitoring
8
monitoring
6
evaluating possibility
4

Similar Publications

A comprehensive review of non-invasive optical and microwave biosensors for glucose monitoring.

Biosens Bioelectron

December 2024

Programa de Pós-Graduação em Engenharia Elétrica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil; Departamento de Engenharia Eletrônica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil. Electronic address:

Frequent glucose monitoring is essential for effective diabetes management. Currently, glucose monitoring is done using invasive methods such as finger-pricking and subcutaneous sensing. However, these methods can cause discomfort, heighten the risk of infection, and some sensing devices need frequent calibration.

View Article and Find Full Text PDF

Monitoring respiration rate (RR) is crucial in various healthcare settings, particularly during demanding (physical) activities where respiratory dynamics are critical indicators of health status. This study aimed to evaluate the accuracy of photoplethysmography (PPG)-based monitoring of RR during high-intensity interval training (HIIT) and its potential applications in healthcare. Between January and March 2024, healthy volunteers participated in a cycling HIIT session with increasing resistance levels.

View Article and Find Full Text PDF

Sensing Technologies for Outdoor/Indoor Farming.

Biosensors (Basel)

December 2024

Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore.

To face the increasing requirement for grains as the global population continues to grow, improving both crop yield and quality has become essential. Plant health directly impacts crop quality and yield, making the development of plant health-monitoring technologies essential. Variable sensing technologies for outdoor/indoor farming based on different working principles have emerged as important tools for monitoring plants and their microclimates.

View Article and Find Full Text PDF

A Highly Stable Electrochemical Sensor Based on a Metal-Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat.

Biosensors (Basel)

December 2024

Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.

The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.

View Article and Find Full Text PDF

Purpose: Thoracic surgery is among the most painful surgeries, postoperative pain can lead to a poor prognosis. This study aimed to explore the analgesic effect of ultrasound-guided continuous rhomboid intercostal and sub-serratus (RISS) plane block Comparison of thoracoscopic intercostal nerve block (ICNB) on postoperative pain management and recovery in patients who underwent Video-Assisted Thoracic Surgery (VATS) Lobectomy.

Methods: This prospective randomized controlled study enrolled patients after VATS Lobectomy who received ultrasound-guided continuous RISS plane block (RISS group) or ICNB (Control group) for postoperative pain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!