Reduction of aldehyde emission and attribution of environment burden in cooking fumes from food stalls using a novel fume collector.

Environ Res

Research Center for Environmental Medicine, Kaohsiung Medical University, 100 Shih-Chuan 1st Rd, Kaohsiung, Taiwan; Graduate Institute of Medicine, College of Medicine, Kaohsiung Medical University, 100 Shih-Chuan 1st Rd, Kaohsiung, Taiwan. Electronic address:

Published: April 2021

Uncontrolled cooking emissions from commercial kitchens are problematic due to their corresponding health effects and malodors. To reduce cooking emissions, medium and large commercial kitchens install air pollution control devices, such as electrostatic precipitators and wet scrubbers, while small-scale commercial cooking workplaces, such as street-food stalls, use smaller, simpler, and less costly filtration and absorption devices. However, these smaller devices may be poorly designed and recirculate cooking emissions in the workplace. The objectives of this study were to design and implement a novel fume collector and evaluate its effectiveness in reducing aldehydes and the corresponding environmental burden emitted by food stalls. Two stalls, which had malodor problems despite the use of fume collectors, volunteered to participate in the study. To increase the efficiency of the existing fume collectors, a new collector was designed comprising two buckets connected in series, each with pollutant absorption (NaClO-surfactant mixed solution) and particulate filtration (activated-carbon filters) components. Total aldehyde concentrations measured at the exhaust outlets of the original and new collectors were 342.2 and 80.8 μg/m for stall A, and 622.7 and 283.1 μg/m for stall B, respectively. The corresponding concentration reductions for stall A and B were 76% and 55%, and the emission rate reductions were 91% (from 749 to 71 g/yr) and 76% (from 1040 g/yr to 248 g/h), respectively. These results demonstrate that the effectiveness of the novel collector at removing cooking fumes was significantly improved. The high efficiency and low-cost nature of the collector make it highly applicable in small-scale commercial kitchens and street-food stalls.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envres.2021.110815DOI Listing

Publication Analysis

Top Keywords

cooking emissions
12
commercial kitchens
12
cooking fumes
8
food stalls
8
novel fume
8
fume collector
8
small-scale commercial
8
street-food stalls
8
fume collectors
8
cooking
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!