Internal standardization was applied to the solid-phase extraction of trace elements using the following commercially available aminocarboxylic acid-type chelating resins: InertSep ME-2, NOBIAS Chelate PA-1, and Presep PolyChelate. The concentration of the trace elements in initial sample solution can be calculated by using the ratio of the added amount of the internal standard element, Y, in the initial sample solution to that in the final solution after the solid-phase extraction, which is proportional to the volume of the sample solution passed through the cartridge, and the ratio of the volume of the initial sample solution to that of a blank solution for preparing the calibration curve. In this solid-phase extraction, strict control of the volumes of the sample solution passed through the cartridge and the final solution after the solid-phase extraction is not needed because these are not used in the calculation of the trace element concentration. The solid-phase extraction with the internal standardization using Y could be applied to the separation and preconcentration of some trace elements, namely Cd, Co, Cu, Fe, Ni, Pb, Ti, and Zn in an artificial seawater spiked with the elements and some certified reference materials, EnviroMAT ES-L-1 Ground Water and EU-L-3 Waste Water, without any interference.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2116/analsci.20P387 | DOI Listing |
Food Chem X
January 2025
Academy of National Food and Strategic Reserves Administration, NFSRA Key Laboratory of Grain and oil quality and safety, Beijing 100037, China.
The contamination of Alternaria toxins poses a potential risk to human health. This study developed a rapid, efficient, and environmentally friendly method for the simultaneous determination of five types of Alternaria toxins in wheat using high-precision and stable isotope liquid chromatography tandem mass spectrometry. The comparison between dilution method and solid-phase extraction method shows that the former achieves satisfactory results with a simple and convenient sample purification method.
View Article and Find Full Text PDFJ Chromatogr Sci
January 2025
Department of Chemistry & Biochemistry, Ohio University, Athens, OH, USA.
The valid method was developed for analyzing empagliflozin in serum/plasma/urine using a molecularly imprinted ghost polymer-solid-phase extraction approach (MISPE) with liquid chromatographic methodology. Methacrylic acid (MAA) was used as the monomer, 2,2 azobis isobutyronitrile as the initiator and ethylene glycol dimethacrylate as the cross-linker in the free radical polymerization procedure. Empagliflozin was loaded onto the polymer and eluted with 1 mL of a 9:1 MeOH:acetic acid solution.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
An easy applicable and selective sample preparation technique has been developed for trace and simultaneously analysis of Glipizide (GLP) and Pravastatin (PST) molecules in biological matrices based on magnetic solid phase extraction (MSPE) and high-performance liquid chromatography (HPLC). A new magnetic adsorbent including FeO@TEOS-Melamine has been synthetized and characterized for extraction studies. Experimental variables of MSPE were examined and optimized step by step such as pH, adsorption and desorption conditions, time effect, etc.
View Article and Find Full Text PDFJ Proteome Res
January 2025
Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.
Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.
View Article and Find Full Text PDFJ Food Sci Technol
January 2025
Food Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh 226001 India.
Unlabelled: Solid phase extraction technique is a widely used sample preparation technique for the extraction of components from complex food matrices. However, there are several parameters in SPE that leads to low recovery, and reproducibility, insufficiently clean extracts and evaporation of volatile compounds. These drawbacks can be addressed through the use of innovative techniques and instrumentation that offers improved efficiency and accuracy for isolation of active constituents from food and beverage samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!