Emergency Department, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan; Department of Emergency, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan; Research Center of Big Data and Meta-Analysis, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan. Electronic address:

Published: March 2021

AI Article Synopsis

  • A systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of ultrasound for small bowel obstruction (SBO), with previous studies showing varied sensitivity (82%-100%) and specificity (54%-100%).
  • The analysis included 15 studies, finding pooled sensitivity at 92% and specificity at 93%, although specificity was notably lower in North America and emergency settings, where CT was the sole reference standard.
  • While ultrasound is generally reliable for diagnosing SBO, practitioners should be cautious due to variability in specificity depending on the study context and diagnostic methods used.

Article Abstract

Purpose: Accurate diagnosis of small bowel obstruction (SBO) remains challenging. The evidence of the diagnostic accuracy of ultrasound varies among studies, with reporting sensitivity ranging from 82 % to 100 % and specificity ranging from 54 % to 100 %. The aim of our study is to perform a systematic review and meta-analysis to investigate the accuracy of ultrasound for diagnosing SBO.

Method: The PubMed, EMBASE, Cochrane Library, Web of Science, and Scopus databases were searched from database inception to March 2020. Randomized controlled trials, quasi randomized studies, and prospective or retrospective cohort studies that evaluated the diagnostic performance of ultrasound for the diagnosis of bowel obstruction in adult patients (age ≥ 16 years) were eligible. The QUADAS-2 tool was used to assess the quality of the included studies. The pooled sensitivities, specificities were analyzed using a bivariate random-effects model. (PROSPERO ID: CRD42020170010).

Results: Fifteen studies, with most rating as a moderate risk of bias, met the inclusion criteria. The pooled sensitivity and specificity were 92 % (95 % CI: 89%-95%) and 93 % (95 % CI: 85%-97%), respectively. Subgroup analysis revealed no significant differences in sensitivity when ultrasound was performed on different continents, in different settings, and under different reference standards. However, the specificity was significantly lower when ultrasound was performed in the North America, in the emergency department, and when computed tomography was used as the only reference standard.

Conclusions: Overall, ultrasound is a highly sensitive and specific tool for the diagnosis of SBO. Using ultrasound to rule in patients with SBO should be used with caution, as variations in the specificity were observed in different study setting, operators from different continents and reference standards used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2021.109565DOI Listing

Publication Analysis

Top Keywords

accuracy ultrasound
12
bowel obstruction
12
diagnostic accuracy
8
ultrasound
8
small bowel
8
systematic review
8
review meta-analysis
8
ranging 100
8
ultrasound performed
8
reference standards
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!