Objective: This study evaluates the effect of dynamic-loading on the microgap of the IAC when different supratructure heights are applied.

Materials And Methods: Forty-eight dental implants (24 each of butt-joint (H) and internal-conical connections (C)) were tested in this study. Each group was further divided into three groups (n = 8) according to the applied suprastructure height (H1, C1: 10 mm, H2, C2: 14 mm and H3, C3: 18 mm). All specimens were subjected to cyclic loading in a chewing-simulator with a load of 98 N for 5 × 10 chewing cycles. The microgap at the IAC was inspected before and after loading, using synchrotron-based micro computed tomography (SRμCT) and light microscopy (LM).

Results: SRμCT revealed an internal microgap range between 0.26 μm and 0.5 μm in the group C, whereas the group H exhibited a microgap range between 0.26 μm and 0.47 μm prior to loading. After chewing simulation, a smaller microgap size in all groups was detected ranging from 0.11 μm to 0.26 μm (group C: 0.11μm-0.26 μm; group H: 0.21μm-0.25 μm). The LM investigation showed mean microgap values at the outer IAC junction before loading from 5.8 μm to 11.3 μm and from 3.9 μm to 7.2 μm after loading. All specimens exhibited a vertical intrusion displacement of the abutment.

Conclusion: Regardless of the crown height, the microgap between the abutment and implant systematically decreased after loading in both butt-joint and internal-conical connections.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2021.104330DOI Listing

Publication Analysis

Top Keywords

synchrotron-based micro
8
micro computed
8
computed tomography
8
microgap
8
microgap iac
8
butt-joint internal-conical
8
internal-conical connections
8
microgap range
8
range 026 μm
8
loading
6

Similar Publications

X-ray fluorescence (XRF) is widely used to analyze elemental distributions in samples. Micro-XRF (µ-XRF), the most basic conventional XRF technique, offers good spatial resolution through precise 2D scanning with a micrometre-sized X-ray source. Recently, synchrotron based XRF analysis platforms have achieved nano-XRF with highly focused X-rays using polycapillary optics or mirrors, leveraging the excellent coherence of synchrotron radiation.

View Article and Find Full Text PDF

Oxidation states and distribution of arsenic (As) in annually laminated (varved) lacustrine deposits were analyzed with a seasonal resolution. This deposit was formed in the mid-Holocene landslide-dammed paleolake in the upper reaches of the Ane River, central Japan and the paleolake watershed consists of the Jurassic accretionary complexes (Mino-Tamba belt) including sedimentary and igneous rocks. In the outcrop, centimeter-to-decimeter-scale silty clay layers alternating with laminated layers are well developed.

View Article and Find Full Text PDF

Pulmonary veno-occlusive disease (PVOD) is a lethal variant of pulmonary hypertension. The degree of pulmonary arterial involvement varies. Here, we compare two PVOD patients who were transplanted at 8 years of age, whereof one is a homozygous mutation carrier.

View Article and Find Full Text PDF

Mammalian hearing operates on three basic steps: 1) sound capturing, 2) impedance conversion, and 3) frequency analysis. While these canonical steps are vital for acoustic communication and survival in mammals, they are not unique to them. An equivalent mechanism has been described for katydids (Insecta), and it is unique to this group among invertebrates.

View Article and Find Full Text PDF

Mechanisms of manganese uptake and long-distance transport in the hyperaccumulator Celosia argentea Linn.

Ecotoxicol Environ Saf

January 2025

College of Environmental Science and Engineering, Guilin University of Technology, Guilin 541004, China. Electronic address:

Celosia argentea Linn. is a hyperaccumulator for the remediation of manganese (Mn)-contaminated soil owing to its rapid growth, high decontamination capacity, and strong stress resistance. However, little is known about the processes involved in long-distance transport of Mn in hyperaccumulators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!