We have developed a process for fabricating patient specific Magnetic Resonance Imaging (MRI) Radio-frequency (RF) receive coil arrays using additive manufacturing. Our process involves spray deposition of silver nanoparticle inks and dielectric materials onto 3D printed substrates to form high-quality resonant circuits. In this paper, we describe the material selection and characterization, process optimization, and design and testing of a prototype 4-channel neck array for carotid imaging. We show that sprayed polystyrene can form a low loss dielectric layer in a parallel plate capacitor. We also demonstrate that by using sprayed silver nanoparticle ink as conductive traces, our devices are still dominated by sample noise, rather than material losses. These results are critical for maintaining high Signal-to-Noise-Ratio (SNR) in clinical settings. Finally, our prototype patient specific coil array exhibits higher SNR (5 × in the periphery, 1.4 × in the center) than a commercially available array designed to fit the majority of subjects when tested on our custom neck phantom. 3D printed substrates ensure an optimum fit to complex body parts, improve diagnostic image quality, and enable reproducible placement on subjects.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7846777 | PMC |
http://dx.doi.org/10.1038/s41598-021-81833-0 | DOI Listing |
Am Fam Physician
January 2025
University of Florida College of Medicine, Gainesville.
Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.
View Article and Find Full Text PDFJ Phys Chem B
January 2025
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China.
Reline, which is composed of choline chloride and urea in a molar ratio of 1:2, is the first and most extensively studied deep eutectic solvent (DES). In certain applications, reline is blended with organic solvents, dimethyl sulfoxide (DMSO) in most cases, to gain improved properties. Therefore, it is crucial to have a profound understanding of the impact of DMSO on the dynamics and structures of the species in the binary mixtures.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Electrical Engineering, Shiraz Branch, Islamic Azad University, Shiraz, Iran.
CNN is considered an efficient tool in brain image segmentation. However, neonatal brain images require specific methods due to their nature and structural differences from adult brain images. Hence, it is necessary to determine the optimal structure and parameters for these models to achieve the desired results.
View Article and Find Full Text PDFMagnetic resonance imaging (MRI) is one of the most commonly used tools in neuroscience. However, it implies exposure to high noise levels. Exposure to noise can lead to temporary or permanent hearing loss, especially when the exposure is long and/or repeated.
View Article and Find Full Text PDFIntroduction: Diagnosing dementia remains challenging in low-income settings due to limited diagnostic options and the absence of definitive biomarkers. The use of brain MRI in the diagnosis of dementia is infrequent in Uganda, and even when it is used, subtle findings like mild regional atrophy are often overlooked, despite being crucial for imaging diagnosis.
Objective: The purpose of this study was to explore the perceptions and practices of imaging personnel and physicians regarding the use of brain MRI as a diagnostic approach for dementia in Uganda.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!