Tuning the Mechanical and Geometric Properties of Electrochemically Aligned Collagen Threads Toward Applications in Biohybrid Robotics.

J Biomech Eng

Biohybrid and Organic Robotics Group, Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213; Department of Biomedical Engineering (Courtesy Appointment), Carnegie Mellon University, Pittsburgh, PA 15213; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15213.

Published: May 2021

AI Article Synopsis

  • Electrochemically aligned collagen (ELAC) threads show promise in biohybrid robotics, requiring careful adjustment of their mechanical and geometric properties for effective muscle actuation.
  • The study explores how varying isoelectric focusing (IF) parameters—such as duration, voltage, and collagen concentration—significantly impacts the resulting ELAC properties.
  • By optimizing these parameters, researchers can create ELAC threads with customizable tensile strength and cross-sectional area, ranging from 198 to 758 MPa in tensile modulus, enhancing their functionality for tissue engineering applications.

Article Abstract

Electrochemically aligned collagen (ELAC) threads fabricated by the isoelectric focusing (IF) of collagen have previously shown potential in tissue engineering and more recently in the fabrication of biohybrid robot structures. For applications in biohybrid robotics, ELAC structures are needed that are both robust and compliant enough to facilitate muscle actuation. However, studies on the effects of IF parameters, and the interactions of such fabrication parameters, on the mechanical and geometric properties of resulting ELAC threads have not been previously found in literature. Understanding the impact of these manufacturing parameters on the material properties is critical to facilitate biohybrid robot design. In this study, the effects of IF duration, IF voltage, and collagen solution concentration were investigated and showed statistically significant effects on adjusting ELAC properties via single-factor experiments. The interactions between parameters exhibited significant joint effects on ELAC property tuning through two-factor experiments. Scanning electron microscopy and 2,4,6-trinitrobenzenesulfonic (TNBS) assays revealed the correlation between high mechanical properties and a combination of low porosity and high degree of crosslinking. By simply tuning IF parameters without changing other fabrication steps, such as crosslinker concentration, ELAC threads with a wide range of mechanical and geometric properties were fabricated. The average tensile modulus of the resulting ELAC threads ranged from 198 ± 90 to 758 ± 138 MPa. The average cross-sectional area ranged from 7756 ± 1000 to 1775 ± 457 μm2. The resultant mapping between IF parameters and ELAC thread properties enabled the production of strong and flexible threads with customizable properties.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.4049956DOI Listing

Publication Analysis

Top Keywords

elac threads
16
mechanical geometric
12
geometric properties
12
properties
8
electrochemically aligned
8
aligned collagen
8
applications biohybrid
8
biohybrid robotics
8
elac
8
biohybrid robot
8

Similar Publications

Collagen-based scaffolds have been widely used in tissue engineering. The alignment of collagen fibers and the degree of crosslinking in engineering tissue scaffolds significantly affect cell activity and scaffold stability. Changes in microarchitecture and crosslinking degree also impact the mechanical properties of collagen scaffolds.

View Article and Find Full Text PDF

Biomimetic scaffolds provide the essential biophysical (e.g., surface topography, stiffness) and biochemical cues (e.

View Article and Find Full Text PDF

Background: Successful management of massive rotator cuff (RC) tendon tears represents a treatment challenge because of the limited intrinsic healing capacity of native tendons and the risk of repair failure. Biologic augmentation of massive RC tears utilizing scaffolds-capable of regenerating bulk tendon tissue to achieve a mechanically functional repair-represents an area of increasing clinical interest.

Purpose: To investigate the histological and biomechanical outcomes after the use of a novel biologic scaffold fabricated from woven electrochemically aligned collagen (ELAC) threads as a suture-holding, fully load-bearing, defect-bridging scaffold with or without mesenchymal stem cells (MSCs) compared with direct repair in the treatment of critically sized RC defects using a rabbit model.

View Article and Find Full Text PDF

Tuning the Mechanical and Geometric Properties of Electrochemically Aligned Collagen Threads Toward Applications in Biohybrid Robotics.

J Biomech Eng

May 2021

Biohybrid and Organic Robotics Group, Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213; Department of Biomedical Engineering (Courtesy Appointment), Carnegie Mellon University, Pittsburgh, PA 15213; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15213.

Article Synopsis
  • Electrochemically aligned collagen (ELAC) threads show promise in biohybrid robotics, requiring careful adjustment of their mechanical and geometric properties for effective muscle actuation.
  • The study explores how varying isoelectric focusing (IF) parameters—such as duration, voltage, and collagen concentration—significantly impacts the resulting ELAC properties.
  • By optimizing these parameters, researchers can create ELAC threads with customizable tensile strength and cross-sectional area, ranging from 198 to 758 MPa in tensile modulus, enhancing their functionality for tissue engineering applications.
View Article and Find Full Text PDF

Despite advancements in surgical techniques and materials for rotator cuff repair procedures, primary repair failures remain common. This study examines the use of electrochemically aligned collagen (ELAC) threads woven into biotextile scaffolds as grafts to repair critical infraspinatus tendon defects in New Zealand White rabbits. Three surgical treatment groups were evaluated: rabbits undergoing direct repair as operative controls, rabbits receiving ELAC scaffolds alone, and rabbits treated with mesenchymal stem cell (MSC)-seeded ELAC scaffolds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!