Purpose: To report a technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (PC-IOL) and analyzing the clinical outcomes and postoperative complications. . 68 eyes of 66 patients who received the technique were studied retrospectively.

Methods: The best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), IOL tilt and decentration, corneal topography (1 and 2), and postoperative complications were determined at 3 months.

Results: The mean preoperative BCVA was 1.63 ± 1.24 logMAR units, and the mean postoperative BCVA was 0.74 ± 0.59 logMAR units at 3 months ( < 0.05). The mean preoperative IOP was 21.9 ± 12.6 mmHg, and the mean postoperative IOP was 16.9 ± 4.5 mmHg at 3 months ( = 0.001). The mean preoperative corneal topography (K1 and K2) was 1 = 42.14 ± 1.91 and 2 = 43.54 ± 1.51; the mean postoperative corneal topography (1 and 2) was 1 = 43.03 ± 2.18 and 2 = 43.40 ± 1.71 at 3 months ( = 0.678 and 0.468, respectively). The mean preoperative spherical equivalent was +11.00 ± 13.19 diopters (), and the mean postoperative spherical equivalent was +0.06 ± 0.86 ( < 0.005). The mean IOL tilt was 2.4 ± 1.7°, and the mean decentration was 0.35 ± 0.21 mm. The mean ACD was 4.31 ± 0.29 mm.

Conclusions: The 27-gauge sutureless intrascleral PC-IOL implantation technique minimizes intraoperative injury, simplifies procedure, and provides good PC-IOL fixation with few postoperative complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826223PMC
http://dx.doi.org/10.1155/2021/8857715DOI Listing

Publication Analysis

Top Keywords

postoperative complications
16
sutureless intrascleral
12
corneal topography
12
posterior chamber
8
chamber intraocular
8
intraocular lens
8
clinical outcomes
8
postoperative
8
outcomes postoperative
8
iol tilt
8

Similar Publications

Background: Nonweightbearing preoperative assessments avoid quadriceps contraction that tends to affect patellar motion and appear to be inaccurate in quantifying anatomic factors, which can lead to incorrect corrections and postoperative complications.

Questions/purposes: (1) Does the relationship of patellar axial malalignment and other anatomic factors change during weightbearing? (2) What anatomic factor was most strongly correlated with recurrent patellar dislocation during weightbearing?

Methods: This prospective, comparative, observational study recruited participants at our institution between January 2023 and September 2023. During this time, all patients with recurrent patellar dislocations received both weightbearing and nonweightbearing CT scans; control patients who received unilateral CT scans because of injuries or benign tumors received both weightbearing and nonweightbearing CT scans.

View Article and Find Full Text PDF

Purpose: The light adjustable lens (LAL) (RxSight, Aliso Viejo, CA) is a premium intraocular lens that allows for correction of residual refractive error and astigmatism following implantation. Herein, we describe the surgical approach and evaluate the visual outcomes of patients following scleral fixation of the LAL.

Methods: Retrospective, single-surgeon surgical case series of 3 patients (3 eyes) with intraocular lens complications, who underwent combined pars plana vitrectomy and sutureless needle assisted intrascleral haptic fixation of the LAL between April 2022, to August 2023.

View Article and Find Full Text PDF

Purpose: To present a novel bended-needle drainage system in vitreous cavity lavage (VCL) for postoperative vitreous cavity hemorrhage (POVCH).

Methods: This retrospective case series include all patients with POVCH who received VCL with the bended-needle drainage system at ophthalmology department of Peking Union Medical College Hospital from January 2022 to May 2024. Patients adopted a supine position that allows preparation and draping.

View Article and Find Full Text PDF

Background: Red breast syndrome (RBS) has been noted in past literature as a possible complication of implant-based breast reconstruction (IBBR) with the use of acellular dermal matrices (ADMs). Since its first appearance in 2009, RBS has drawn growing medical attention with reported incidence ranging from 7%-9%. There has been a noted decrease in the emergence of RBS despite its inclusion among the analyzed complications in a number of studies.

View Article and Find Full Text PDF

Background: While there is mounting evidence that closed suction drains are not necessary, there is a paucity of literature to demonstrate that drains are harmful after breast reduction. The purpose of this study was to investigate the effect of drains on postoperative seroma, hematoma, and infection, as well as elucidate any risk factors that may be implicated in the development of these complications.

Methods: A retrospective cohort study was conducted of all reduction mammaplasty procedures at our university medical center between 2010-2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!