A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Screening of apathetic elderly adults using kinematic information in gait and sit-to-stand/stand-to-sit movements measured with Doppler radar. | LitMetric

This paper presents a Doppler radar apathy-screening technique applied to elderly people based on their basic daily activities of walking and movements of sit-to-stand and stand-to-sit (STS). Our Doppler radar system remotely measured the kinematic parameters of the movements of 78 community-dwelling elderly adults (27 apathetic participants and 51 non-apathetic ones). Subsequently, logistic regression models using the measured kinematic parameters of gait and sit-to-stand/stand-to-sit movements were constructed for screening. The experimental results verified that, although the model using gait parameters could screen an apathetic group with a sensitivity of 85.2% and a specificity of 58.8%, the model using the STS parameters achieved better screening accuracies with a sensitivity of 88.9% and a specificity of 76.5%. These results reveal that the kinematic information of STS movements is significantly more effective at detecting apathy than is the gait information, which is otherwise regarded to be effective in conventional epidemiological studies.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1460458221990051DOI Listing

Publication Analysis

Top Keywords

doppler radar
12
elderly adults
8
gait sit-to-stand/stand-to-sit
8
sit-to-stand/stand-to-sit movements
8
measured kinematic
8
kinematic parameters
8
movements
5
screening apathetic
4
apathetic elderly
4
kinematic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!