Background/aim: Wearing a mouthguard reduces the risk of sport-related injuries, but the thickness has a large effect on its efficacy and safety. The aim of this study was to investigate the effect on the thickness of a single-layer mouthguard of the positional relationship between the suction port of the vacuum forming device and the model.
Materials And Methods: Ethylene-vinyl-acetate sheets of 4.0-mm-thickness and a vacuum forming machine were used. Two hard plaster models were prepared: Model A was 25-mm at the anterior teeth and 20-mm at the molar, and model B was trimmed so the bucco-lingual width was half that of model A. Three model positions on the forming table were examined: (a) P20, where the model anterior rim was located in front of the suction port, (b) P30, where the model anterior rim and front edge of the suction port were close, and (c) P43, where the model anterior rim and palatal rim were located on the suction port. Six mouthguards were fabricated for each condition. Thickness differences due to model form and model position were analyzed.
Results: Thickness differences due to model form were observed at the incisal edge and labial surface, and model A was significantly thicker than model B in P43 (P<.01). The thickness of the incisal edge and labial surface was significantly greatest in P43 for model A, but in P30 for model B.
Conclusions: The effect of the model position on the forming table on suppressing the labial thickness reduction of the mouthguard depended on the bucco-lingual width of the model. It is important to position the model anterior rim away from the sheet frame if the bucco-lingual width of the model is large and to place the model anterior rim in front of the suction port if the width is small.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/edt.12646 | DOI Listing |
Asian J Endosc Surg
December 2024
Department of Obstetrics and Gynecology, Kawasaki Medical School, Okayama, Japan.
Introduction: The three-arm approach is mainly selected, despite the multiple robotic arms in da Vinci Xi. This type of surgical setup may provide less autonomy to the console surgeon and result in greater dependence on the bedside surgical assistant. Therefore, the 4th arm is used instead of the assist port, which is why we developed "pure" robot simple hysterectomy (PRSH) as a novel surgical technique, in which all ports are operated by robotic arms.
View Article and Find Full Text PDFObjective: This study aimed to evaluate the intraoperative use of a drain line for smoke suction during robotic thyroidectomy using a gas insufflation one-step single-port transaxillary (GOSTA) approach and its impact on surgical outcomes.
Study Design: Retrospective cohort study.
Setting: University tertiary care facility.
Aesthet Surg J Open Forum
November 2024
Background: Liposuction is the most common cosmetic plastic surgery procedure in the United States, and lipo-aspiration for fat grafting is gaining in popularity. The results are effective, but complications include seroma, contour irregularities, skin necrosis, and even death. Scarring, dehiscence, and infection at the port site, although minor, are a common and less-discussed problem.
View Article and Find Full Text PDFFront Med Technol
November 2024
Department of BioMechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, Netherlands.
Thrombus removal from the human body is facilitated through the utilization of aspiration catheters during minimally invasive thrombectomy procedures, where a pressure differential guides the targeted tissue through a flexible tubular medical instrument. In this paper, we present a patent analysis of thrombectomy aspiration catheter tip designs sourced from the EspaceNet database. Our findings reveal that enhancing the operability of aspiration catheters can be achieved by improving ease of positioning or suction capacity, whether through active or passive means.
View Article and Find Full Text PDFCureus
October 2024
Department of Surgery, Saga University Faculty of Medicine, Saga, JPN.
Robotic liver resection (RLR) faces challenges in parenchymal dissection due to device limitations, necessitating the development of a safe, efficient, and versatile method for its widespread use. We introduce our six-port RLR approach utilizing the double bipolar clamp-crush method with saline drops to overcome these device limitations. This method, combined with robotic bipolar forceps, maximizes the advantages of RLR by leveraging its multi-joint functionality and facilitates the dissection of strong, fibrotic liver tissue through the use of bipolar energy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!